EUVIMEDEUVIMED entdecken
Crossref

Flexible microcolumn array-based silk fibroin for sweat glucose monitoring

Dajiang Kuang, Yongsong Tan, Weiyi Han, Yunjie Yin, Chaoxia Wang

Analytica Chimica Acta · 2025

DOI: 10.1016/j.aca.2025.343857 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Dajiang Kuang und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Textile Science and Engineering, Jiangnan University, 1800Lihu Road, Wuxi, 214122, China. Hauptthemen laut MEDLINE: Fibroins, Sweat, Glucose, Biosensing Techniques. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flexible sweat sensors possess the special potential for continuous non-invasive monitoring of human blood glucose. We put forward a flexible microcolumn array sensor, which is designed for health monitoring by means of detecting glucose levels in sweat and capturing physiological signals related to human movement. With the combination of silk fibroin (SF), waterborne polyurethane (PU), and multi-walled carbon nanotubes (MWCNT), this microcolumn film electrode is able to effectively function as a strain sensor benefiting from the superior mechanical performance of PU. The obtained strain sensor exhibits a rapid response time of 0.3s and demonstrates robust stability over 500 cycles, efficiently capturing human pulse and hand movement signals. Prussian Blue (PB) is deposited on the surface of the microcolumn electrode and glucose oxidase (GOx) is sprayed to construct a glucose sensor that can accurately detect glucose in human sweat. The microcolumn array sensor shows and exhibits an excellent sensitivity of 35.28 μA/mM·cm2 within a dynamic range of 0.1-1 mM, and a limit of detection (LOD) of 0.004 mM, which reveals outstanding glucose sensing performance. This microcolumn array sensor demonstrates the potential of silk fibroin in crafting portable, high-performance electrochemical wearable medical devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FibroinsSweatGlucoseBiosensing TechniquesHumansGlucose OxidaseElectrochemical TechniquesNanotubes, CarbonElectrodesWearable Electronic DevicesPolyurethanesLimit of Detection

Stichwörter der Autor:innen

Glucose sensorMicrocolumn arraySilk fibroinStrain sensorWaterborne polyurethane

Substanzen

FibroinsGlucoseGlucose OxidaseNanotubes, CarbonPolyurethanes

Autor:innen und Institutionen

  • College of Textile Science and Engineering, Jiangnan University, 1800Lihu Road, Wuxi, 214122, China.
  • College of Textile Science and Engineering, Jiangnan University, 1800Lihu Road, Wuxi, 214122, China. Electronic address: wangchaoxia@sohu.com.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Kuang, D., Tan, Y., Han, W., Yin, Y., & Wang, C. (2025). Flexible microcolumn array-based silk fibroin for sweat glucose monitoring. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.343857

Vancouver

Kuang D, Tan Y, Han W, Yin Y, Wang C. Flexible microcolumn array-based silk fibroin for sweat glucose monitoring. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2025.343857

BibTeX
@article{Kuang2025,
  author = {Kuang, Dajiang and Tan, Yongsong and Han, Weiyi and Yin, Yunjie and Wang, Chaoxia},
  title = {Flexible microcolumn array-based silk fibroin for sweat glucose monitoring},
  journal = {Analytica Chimica Acta},
  year = {2025},
  doi = {10.1016/j.aca.2025.343857}
}
Kostenlos starten →