Evaluation of Shear Bond Strength in the Repair of Additively and Subtractively Manufactured CAD/CAM Materials Using Bulk-Fill Composites
Biomimetics · 01.07.2025 · 10 (7) · 433
DOI: 10.3390/biomimetics10070433 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomimetics, online erschienen am 01.07.2025. Verfasst von Selinsu Öztürk und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul 34854, Turkey. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Biomimetic restorative protocols aim to preserve natural tooth structure while enhancing restoration longevity. This in vitro study aimed to evaluate the shear bond strength (SBS) in the repair of additively and subtractively manufactured CAD/CAM materials using bulk-fill resin composites and to assess the effect of thermocycling. Forty rectangular specimens (14.5 × 7 × 3 mm) were prepared from Grandio Blocs (GB, VOCO) and VarseoSmile CrownPlus (VS, BEGO), and thermocycled (5000 cycles, 5–55 °C, 20 s dwell time). All surfaces were roughened with 50 μm Al2O3. Samples were repaired using VisCalor (VCB, VOCO) and Charisma Bulk Flow One (CBO, Kulzer) composites (n = 10 per group) with their respective adhesives. Each group was further divided into immediate and post-thermocycling subgroups. All specimens were tested under shear force until failure, and failure types were examined under a stereomicroscope. Representative samples were examined by SEM to evaluate filler morphology. Statistical analysis was performed with SPSS v23 (p < 0.05). No statistically significant differences in SBS were found between groups (p > 0.05). Mean SBS values were highest in VS-CBO and lowest in GB-CBO. Cohesive failures were more frequent in immediate groups, while adhesive failures predominated after thermocycling. Bulk-fill composites did not influence the repair bond strength of indirect materials. Thermocycling affected the failure type, though not the SBS values.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul 34854, Turkey.
- Department of Restorative Dentistry, Institute of Health Sciences, Marmara University, Istanbul 34865, Turkey.
- Department of Prosthodontics, Faculty of Dentistry, Marmara University, Istanbul 34854, Turkey.
ORCID-Profile: Selinsu Öztürk, Ayşe Aslı Şenol, Pınar Yılmaz Atalı, Bilge Tarçın
Zitieren
APA
Öztürk, S., Altuntaş, E., Şenol, A. A., Kahramanoğlu, E., Yılmaz Atalı, P., Tarçın, B., & Türkmen, C. (2025). Evaluation of Shear Bond Strength in the Repair of Additively and Subtractively Manufactured CAD/CAM Materials Using Bulk-Fill Composites. Biomimetics, 10(7), 433. https://doi.org/10.3390/biomimetics10070433
Vancouver
Öztürk S, Altuntaş E, Şenol AA, Kahramanoğlu E, Yılmaz Atalı P, Tarçın B, et al. Evaluation of Shear Bond Strength in the Repair of Additively and Subtractively Manufactured CAD/CAM Materials Using Bulk-Fill Composites. Biomimetics. 2025;10(7):433. doi:10.3390/biomimetics10070433
BibTeX
@article{ztrk2025,
author = {Öztürk, Selinsu and Altuntaş, Ezgi and Şenol, Ayşe Aslı and Kahramanoğlu, Erkut and Yılmaz Atalı, Pınar and Tarçın, Bilge and Türkmen, Cafer},
title = {Evaluation of Shear Bond Strength in the Repair of Additively and Subtractively Manufactured CAD/CAM Materials Using Bulk-Fill Composites},
journal = {Biomimetics},
year = {2025},
volume = {10},
number = {7},
pages = {433},
doi = {10.3390/biomimetics10070433}
}
EUVIMED