Comparative Study of Fused Deposition Modeling-Manufactured Polylactic Acid (PLA) Screws and Commercial Polyether Ether Ketone (PEEK) and Poly(L-lactide-co-D,L-lactide) (PLDLLA) Implants for Orthopedic Fixation: An In Vivo Assessment
Biomolecules · 23.11.2026 · 16 (12) · 1701
DOI: 10.3390/biom16121701 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomolecules, online erschienen am 23.11.2026. Verfasst von Carolina Valdez-Velázquez und 15 weiteren Autor:innen. Die Arbeit nennt 95 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Orthopedic fixation requires implants that combine mechanical stability with geometries adapted to anatomical and surgical requirements. The biodegradability, tunable mechanical properties, and geometric versatility of polylactic acid (PLA) make it attractive for patient-specific orthopedic implants; however, the long-term in vivo response of Fused Deposition Modeling (FDM)-manufactured PLA screws remains insufficiently understood. This study evaluated the postoperative response from early healing through eight months, comparing FDM-fabricated PLA screws with clinically established polyether ether ketone (PEEK) and poly(L-lactide-co-D,L-lactide) (PLDLLA) screws. PLA screws were fabricated layer by layer by FDM, enabling application-specific geometries, including fine thread pitches and customized features. The materials were characterized by dynamic mechanical analysis (DMA) and Fourier-transform infrared spectroscopy (FTIR), while computed tomography (CT) and histology evaluated structural integrity and the bone–implant interface over time. All implants maintained structural integrity throughout eight months without premature degradation. PLA exhibited progressive new bone formation and partial tissue integration, with increasing bone maturation over time. PEEK showed predominantly fibrointegrative healing early, followed by increased mature bone densification at long-term implantation. PLDLLA promoted rapid tissue integration and dense mature cortical bone formation from the early stage. Overall, FDM enabled the fabrication of biodegradable PLA screws with application-specific and potentially patient-tailored geometries, supporting their potential for osteoconductive orthopedic fixation.
Zitieren
APA
Valdez-Velázquez, C., Gómez-Salgado, B. A., Aragón-García, B., Portillo-Ortiz, N. K., Luevano-González, A., Maynez-Villalobos, J. M., Chung-Arceo, D., Sáenz-Flores, E., Buenabad, L., Vázquez-Olvera, G., Sánchez-Duarte, R. G., Martínez-García, A., Carrera-Gutiérrez, K., Berumen-Nafarrate, E., Gómez-Batres, R., & Orozco-Carmona, V. M. (2026). Comparative Study of Fused Deposition Modeling-Manufactured Polylactic Acid (PLA) Screws and Commercial Polyether Ether Ketone (PEEK) and Poly(L-lactide-co-D,L-lactide) (PLDLLA) Implants for Orthopedic Fixation: An In Vivo Assessment. Biomolecules, 16(12), 1701. https://doi.org/10.3390/biom16121701
Vancouver
Valdez-Velázquez C, Gómez-Salgado BA, Aragón-García B, Portillo-Ortiz NK, Luevano-González A, Maynez-Villalobos JM, et al. Comparative Study of Fused Deposition Modeling-Manufactured Polylactic Acid (PLA) Screws and Commercial Polyether Ether Ketone (PEEK) and Poly(L-lactide-co-D,L-lactide) (PLDLLA) Implants for Orthopedic Fixation: An In Vivo Assessment. Biomolecules. 2026;16(12):1701. doi:10.3390/biom16121701
BibTeX
@article{ValdezVelzquez2026,
author = {Valdez-Velázquez, Carolina and Gómez-Salgado, Brissa Aylin and Aragón-García, Brianda and Portillo-Ortiz, Nadia Karina and Luevano-González, Arturo and Maynez-Villalobos, Jesús Manuel and Chung-Arceo, David and Sáenz-Flores, Edith and Buenabad, Lorenzo and Vázquez-Olvera, Gregorio and Sánchez-Duarte, Reyna Guadalupe and Martínez-García, Alfredo and Carrera-Gutiérrez, Karime and Berumen-Nafarrate, Edmundo and Gómez-Batres, Roberto and Orozco-Carmona, Victor M.},
title = {Comparative Study of Fused Deposition Modeling-Manufactured Polylactic Acid (PLA) Screws and Commercial Polyether Ether Ketone (PEEK) and Poly(L-lactide-co-D,L-lactide) (PLDLLA) Implants for Orthopedic Fixation: An In Vivo Assessment},
journal = {Biomolecules},
year = {2026},
volume = {16},
number = {12},
pages = {1701},
doi = {10.3390/biom16121701}
}
EUVIMED