Trueness and Precision of Intraoral Scanners for 3D-Printed Orthodontic Models with Attachments: An In Vitro Comparative Study
Bioengineering · 2026-06-20 · 13 (6) · 709
DOI: 10.3390/bioengineering13060709 ↗At a glance
Journal article in Bioengineering, published online on 2026-06-20. Written by Fırat Oğuz and 2 co-authors. Institution: Department of Orthodontics, Faculty of Dentistry, İnönü University, Malatya 44280, Türkiye. 32 references. The full text is freely available (open access, CC BY 4.0). Funded by: Inonu University, İnönü University.
Abstract (original language)
Background
Advances in additive manufacturing and CAD/CAM technologies have expanded the use of 3D-printed orthodontic models in digital aligner workflows. Intraoral scanners (IOS) are critical for accurately capturing attachment geometries and dental morphology during these workflows. However, comparative evidence regarding IOS accuracy in models with complex orthodontic structures remains limited. Therefore, this study aimed to compare the trueness and precision of five IOS using 3D-printed orthodontic models with attachments.
Methods
In this in vitro study, thirty independent single-arch 3D-printed models (either maxillary or mandibular) with orthodontic attachments were scanned twice with each IOS. The Smart Optics Vinyl laboratory scanner served as the reference scanner. Scans were aligned and superimposed in CloudCompare, and root mean square (RMS) deviation values were calculated to evaluate accuracy. Nonparametric Kruskal–Wallis and Dunn tests were applied (α = 0.05).
Results
Significant differences were found among scanners for both trueness and precision (p < 0.001). Primescan, TRIOS 3, and iTero element 5D demonstrated comparable trueness (p > 0.05) and outperformed Rapideye MI-1000 (p < 0.001). iTero element 2 plus showed slightly lower accuracy but remained clinically acceptable. Primescan achieved the highest precision, significantly exceeding iTero element 2 plus, iTero element 5D, and Rapideye MI-1000 (p < 0.01). TRIOS 3 also exhibited excellent repeatability, comparable to Primescan (p = 1.000).
Conclusions
All intraoral scanners, except Rapideye MI-1000, demonstrated accuracy levels generally considered clinically acceptable for digital orthodontic and additive manufacturing workflows. Primescan, TRIOS 3, and iTero element 5D exhibited similarly high trueness, while Primescan showed the most consistent precision. The ability of these scanners to reproduce fine anatomical details may improve the reliability of 3D-printed orthodontic models and in-office aligner production workflows.
Subjects
Author keywords
Authors and institutions
- Department of Orthodontics, Faculty of Dentistry, İnönü University, Malatya 44280, Türkiye.
- MEF Dental Oral and Dental Health Clinic, Malatya 44280, Türkiye.
ORCID profiles: Fırat Oğuz, Sabahattin Bor
Funding
- Inonu University
- İnönü University
Cite
APA
Oğuz, F., Oğuz, H. G., & Bor, S. (2026). Trueness and Precision of Intraoral Scanners for 3D-Printed Orthodontic Models with Attachments: An In Vitro Comparative Study. Bioengineering, 13(6), 709. https://doi.org/10.3390/bioengineering13060709
Vancouver
Oğuz F, Oğuz HG, Bor S. Trueness and Precision of Intraoral Scanners for 3D-Printed Orthodontic Models with Attachments: An In Vitro Comparative Study. Bioengineering. 2026;13(6):709. doi:10.3390/bioengineering13060709
BibTeX
@article{Ouz2026,
author = {Oğuz, Fırat and Oğuz, Handan Göze and Bor, Sabahattin},
title = {Trueness and Precision of Intraoral Scanners for 3D-Printed Orthodontic Models with Attachments: An In Vitro Comparative Study},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {6},
pages = {709},
doi = {10.3390/bioengineering13060709}
}
EUVIMED