EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and Evaluation of Stand-to-Sit and Sit-to-Stand Control Protocols for a HIP–Knee–Ankle–Foot Prosthesis with a Motorized Hip Joint

Farshad Golshan iD, Natalie Baddour iD, Hossein Gholizadeh iD, David Nielen, Edward D Lemaire iD

Bioengineering · 31.12.2025 · 13 (1) · 48

DOI: 10.3390/bioengineering13010048 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 31.12.2025. Verfasst von Farshad Golshan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5, Canada. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mitacs, Natural Sciences and Engineering Research Council of Canada, Mitacs and Össur.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Sitting and standing with conventional hip–knee–ankle–foot (HKAF) prostheses are demanding tasks for hip disarticulation (HD) amputees due to the passive nature of current prosthetic hip joints that cannot assist with moment generation. This study developed a sitting and standing control strategy for a motorized hip joint and evaluated whether providing active assistance reduces the intact side demand of these activities.

Methods

A dedicated control strategy was developed and implemented for a motorized hip prosthesis (Power Hip) compatible with existing prosthetic knees, feet, and sockets. One HD participant was trained to perform sitting and standing tasks using the Power Hip. Its performance was compared with the participant’s prescribed passive HKAF prosthesis through measurements of ground reaction forces (GRFs), joint moments, and activity durations. GRFs were collected using force plates, kinematics were captured via Theia3D markerless motion capture, and joint moments were computed in Visual3D.

Results

The Power Hip enabled more symmetric limb loading and faster stand-to-sit transitions (1.22 ± 0.08 s vs. 2.62 ± 0.41 s), while slightly prolonging sit-to-stand (1.69 ± 0.49 s vs. 1.22 ± 0.40 s) compared to the passive HKAF. The participant exhibited reduced intact-side loading impulses during stand-to-sit (4.97 ± 0.78 N∙s/kg vs. 15.06 ± 2.90 N∙s/kg) and decreased reliance on upper-limb support. Hip moment asymmetries between the intact and prosthetic sides were also reduced during both sit-to-stand (−0.18 ± 0.09 N/kg vs. −0.69 ± 0.67 N/kg) and stand-to-sit transitions (0.77 ± 0.20 N/kg vs. 2.03 ± 0.58 N/kg).

Conclusions

The prototype and control strategy demonstrated promising improvements in sitting and standing performance compared to conventional passive prostheses, reducing the physical demand on the intact limb and upper body.

Schlagwörter

Stichwörter der Autor:innen

impedance-controlkinematicskineticspower hipsittingstanding up

Autor:innen und Institutionen

  • Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5, Canada.
  • Faculty of Medicine, University of Ottawa, Ottawa, ON K1H 8M5, Canada.
  • Ottawa Hospital Research Institute, Ottawa, ON K1H 8L6, Canada.
  • Nielen Orthotics and Prosthetics, Ottawa, ON K2A 2C5, Canada.

ORCID-Profile: Farshad Golshan, Natalie Baddour, Hossein Gholizadeh, Edward D Lemaire

Förderung

  • Mitacs
  • Natural Sciences and Engineering Research Council of Canada
  • Mitacs and Össur

Zitieren

APA

Golshan, F., Baddour, N., Gholizadeh, H., Nielen, D., & Lemaire, E. D. (2025). Design and Evaluation of Stand-to-Sit and Sit-to-Stand Control Protocols for a HIP–Knee–Ankle–Foot Prosthesis with a Motorized Hip Joint. Bioengineering, 13(1), 48. https://doi.org/10.3390/bioengineering13010048

Vancouver

Golshan F, Baddour N, Gholizadeh H, Nielen D, Lemaire ED. Design and Evaluation of Stand-to-Sit and Sit-to-Stand Control Protocols for a HIP–Knee–Ankle–Foot Prosthesis with a Motorized Hip Joint. Bioengineering. 2025;13(1):48. doi:10.3390/bioengineering13010048

BibTeX
@article{Golshan2025,
  author = {Golshan, Farshad and Baddour, Natalie and Gholizadeh, Hossein and Nielen, David and Lemaire, Edward D},
  title = {Design and Evaluation of Stand-to-Sit and Sit-to-Stand Control Protocols for a HIP–Knee–Ankle–Foot Prosthesis with a Motorized Hip Joint},
  journal = {Bioengineering},
  year = {2025},
  volume = {13},
  number = {1},
  pages = {48},
  doi = {10.3390/bioengineering13010048}
}