Novel pencil-beam scanning proton lattice radiation therapy for the treatment of bulky liver cancer: dosimetric comparison with VMAT-lattice radiotherapy
Frontiers in Oncology · 04.02.2026 · 15
DOI: 10.3389/fonc.2025.1731259 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 04.02.2026. Verfasst von Yuting Li und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Spatially fractionated radiotherapy (SFRT) delivered as lattice radiotherapy (LRT) creates high-dose ‘vertex’ subvolumes (VTVH) embedded within low-dose ‘valley’ regions (VTVL) to intensify intratumoral dose while minimizing radiation dose and toxicity to organs at risk (OARs). We developed a pencil-beam scanning (PBS) intensity modulated proton therapy (IMPT) LRT planning approach and dosimetrically compared it directly with contemporary photon-based volume modulated arc therapy (VMAT) LRT for liver cancer with bulky tumors.
Methods
Twenty-one retrospective liver cases were replanned in RayStation to a single fraction of 20 Gy to VTVH with explicit VTVL sparing (mean dose <5Gy). Primary dosimetric endpoints were VTVH D80 and VTVL mean dose (analogous to mean valley dose), with secondary endpoints of VTVH/VTVL ratios (PVDR-like metrics at D80/D90/D100), VTVL D5/D80, GTV D10/D90, and planning risk volume (PRV) 0.03 cm³ hotspots. Statistical analysis consisted of paired tests (t-test or Wilcoxon signed-rank) after assessing data normality (Shapiro-Wilk tests) and using α=0.05 for significance.
Results
Compared with photon VMAT-LRT, IMPT-LRT significantly reduced VTVL mean dose (p<0.00001) and increased VTVH D80 (p<0.00001), yielding higher VTVH/VTVL ratios at D80/D90/D100 (all p<0.00001). Gross tumor volume (GTV) heterogeneity (D20/D80) significantly increased with proton-LRT (p<0.00001) and OAR hot-spot metrics (PRV D0.03cc) were comparable between both modalities (p=0.71).
Conclusions
A robust PBS proton-LRT planning approach was developed and compared to photon VMAT-LRT for large liver tumors. Our IMPT-LRT approach maximizes peak-to-valley separation and simultaneously maintains target coverage while significantly reducing valley dose, as compared to traditional VMAT-LRT. These findings support future prospective clinical evaluation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States.
- Graduate School of Biomedical Sciences, University of Texas Health Science Center at Houston/The University of Texas MD Anderson Cancer Center, Houston, TX, United States.
- School of Health Professions, The University of Texas MD Anderson Cancer Center, Houston, TX, United States.
- Department of Gastrointestinal Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States.
Zitieren
APA
Li, Y., Martin-Paulpeter, R. M., Chung, C. V., Aguilar, M. A., Matias, C. A., Delgado, A., Nair, S. S., Court, L. E., Perles, L., Sahoo, N., Zhu, R. X., Poenisch, F., Flint, D. B., Sawakuchi, G. O., Beddar, S., Koay, E., Baker, J. S., Ludmir, E. B., & Niedzielski, J. S. (2026). Novel pencil-beam scanning proton lattice radiation therapy for the treatment of bulky liver cancer: dosimetric comparison with VMAT-lattice radiotherapy. Frontiers in Oncology, 15. https://doi.org/10.3389/fonc.2025.1731259
Vancouver
Li Y, Martin-Paulpeter RM, Chung CV, Aguilar MA, Matias CA, Delgado A, et al. Novel pencil-beam scanning proton lattice radiation therapy for the treatment of bulky liver cancer: dosimetric comparison with VMAT-lattice radiotherapy. Frontiers in Oncology. 2026;15. doi:10.3389/fonc.2025.1731259
BibTeX
@article{Li2026,
author = {Li, Yuting and Martin-Paulpeter, Rachael M and Chung, Christine V and Aguilar, Miguel A and Matias, Carlos A and Delgado, Adrian and Nair, Saurabh S and Court, Laurence E and Perles, Luis and Sahoo, Narayan and Zhu, Ronald X and Poenisch, Falk and Flint, David B and Sawakuchi, Gabriel O and Beddar, Sam and Koay, Eugene and Baker, Jamie S and Ludmir, Ethan B and Niedzielski, Joshua S},
title = {Novel pencil-beam scanning proton lattice radiation therapy for the treatment of bulky liver cancer: dosimetric comparison with VMAT-lattice radiotherapy},
journal = {Frontiers in Oncology},
year = {2026},
volume = {15},
doi = {10.3389/fonc.2025.1731259}
}