Pencil beam scanning proton lattice radiotherapy: single-field versus multi-field optimization

Shouyi Wei, Lee Xu, Hang Qi, Ajay Zheng, Milo Vermeulen, Annemarie Shepherd, Kaled Alektiar, Nancy Y Lee, Richard Bakst, Chandan Guha, Pingfang Tsai, Minglei Kang und 6 weitere

Frontiers in Oncology · 20.01.2026 · 15

DOI: 10.3389/fonc.2025.1716722 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 20.01.2026. Verfasst von Shouyi Wei und 17 weiteren Autor:innen. Beteiligte Einrichtung: New York Proton Center, New York, NY, United States. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the advantages and disadvantages of single-field versus multi-field optimization in the clinical implementation of pencil beam scanning (PBS) proton lattice radiotherapy (LRT).

Methods

LRT proton plans were created retrospectively for 12 patients with head-and-neck, thoracic, or abdominal bulky tumors, averaging a gross tumor volume (GTV) of 1011.1 cc (between 333 cc and 3546 cc). The plans were developed in the RayStation treatment planning system (version 2023B), adhering to established consensus guidelines for prescription dose and planning goals. For each plan, 6–8 vertices with an average diameter of 1.4 cm were positioned approximately 3.5 cm apart. The prescription was 18 Gy to each vertex and 3 Gy to the GTV. Single-field optimization (SFO) and multi-field optimization (MFO) techniques were employed. The dosimetric parameters of GTV Dmean, D95%, generalized equivalent uniform dose (gEUD a=-10), vertex D90%, peak-to-valley dose ratio (PVDR), and skin D1% were used for plan quality assessment. Plan robustness was also investigated by comparing dose metrics between the nominal and second worst-case scenarios in the robust analysis.

Results

For all 12 patients, both SFO and MFO plans achieved a PVDR close to 4 across the three treatment sites. No significant differences in primary dose metrics were observed between SFO and MFO plans, except for skin D1%, which was reduced by an average of 25% in the MFO plans (p<0.05). Robustness evaluation indicated larger deviations in PVDR, GTV Dmean, and skin D1% between nominal and second worst-case scenarios for MFO plans compared to SFO (p<0.05).

Conclusion

Both SFO and MFO techniques can be reliably implemented with current proton beam quality standards and advanced treatment planning algorithms. While SFO offers better plan robustness in maintaining the originally optimized metrics under various treatment-related uncertainties, MFO enhances the ability to spare critical organs.

Schlagwörter

Stichwörter der Autor:innen

MFOSFOlattice radiation therapy (LRT)pencil beam scanningproton therapy

Autor:innen und Institutionen

  • New York Proton Center, New York, NY, United States.
  • Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, United States.
  • Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, NY, United States.
  • Department of Radiation Oncology, Albert Einstein College of Medicine, New York, NY, United States.
  • University of Wisconsin-Madison Department of Human Oncology, Madison, WI, United States.
  • Executive Medical Physics Associates, Miami, FL, United States.

Förderung

  • NCI NIH HHS

Zitieren

APA

Wei, S., Xu, L., Qi, H., Zheng, A., Vermeulen, M., Shepherd, A., Alektiar, K., Lee, N. Y., Bakst, R., Guha, C., Tsai, P., Kang, M., Wu, X., Yacoub, I., Choi, J. I., Chhabra, A., Simone, C. B., & Lin, H. (2026). Pencil beam scanning proton lattice radiotherapy: single-field versus multi-field optimization. Frontiers in Oncology, 15. https://doi.org/10.3389/fonc.2025.1716722

Vancouver

Wei S, Xu L, Qi H, Zheng A, Vermeulen M, Shepherd A, et al. Pencil beam scanning proton lattice radiotherapy: single-field versus multi-field optimization. Frontiers in Oncology. 2026;15. doi:10.3389/fonc.2025.1716722

BibTeX
@article{Wei2026,
  author = {Wei, Shouyi and Xu, Lee and Qi, Hang and Zheng, Ajay and Vermeulen, Milo and Shepherd, Annemarie and Alektiar, Kaled and Lee, Nancy Y and Bakst, Richard and Guha, Chandan and Tsai, Pingfang and Kang, Minglei and Wu, Xiaodong and Yacoub, Irini and Choi, Jehee Isabelle and Chhabra, Arpit and Simone, Charles B and Lin, Haibo},
  title = {Pencil beam scanning proton lattice radiotherapy: single-field versus multi-field optimization},
  journal = {Frontiers in Oncology},
  year = {2026},
  volume = {15},
  doi = {10.3389/fonc.2025.1716722}
}