Fachartikel in der Zeitschrift Frontiers in Nutrition, online erschienen am 03.12.2024. Verfasst von David P Looney und 6 weiteren Autor:innen. Beteiligte Einrichtung: United States Army Research Institute of Environmental Medicine (USARIEM), Natick, MA, United States. Die Arbeit wurde bisher 90-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses.
Purpose
Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA).
Methods
Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA).
Results
Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg).
Conclusion
Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- United States Army Research Institute of Environmental Medicine (USARIEM), Natick, MA, United States.
- Maximize Human Performance, LLC, Framingham, MA, United States.
- CoachMePlus, Buffalo, NY, United States.
- Oak Ridge Institute for Science and Education (ORISE), Oak Ridge, TN, United States.
- Center for Research and Education in Special Environments, Department of Exercise and Nutrition Sciences, University at Buffalo, Buffalo, NY, United States.
Zitieren
APA
Looney, D. P., Schafer, E. A., Chapman, C. L., Pryor, R. R., Potter, A. W., Roberts, B. M., & Friedl, K. E. (2024). Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components. Frontiers in Nutrition, 11. https://doi.org/10.3389/fnut.2024.1491931
Vancouver
Looney DP, Schafer EA, Chapman CL, Pryor RR, Potter AW, Roberts BM, et al. Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components. Frontiers in Nutrition. 2024;11. doi:10.3389/fnut.2024.1491931
BibTeX
@article{Looney2024,
author = {Looney, David P and Schafer, Erica A and Chapman, Christopher L and Pryor, Riana R and Potter, Adam W and Roberts, Brandon M and Friedl, Karl E},
title = {Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components},
journal = {Frontiers in Nutrition},
year = {2024},
volume = {11},
doi = {10.3389/fnut.2024.1491931}
}
EUVIMED