Validity of total body water measured by multi-frequency bioelectrical impedance devices in a multi-ethnic sample

Malia N M Blue, Grant M Tinsley, Katie R Hirsch, Eric D Ryan, Bennett K Ng, Abbie E Smith-Ryan

Clinical Nutrition ESPEN · 2023-04 · 54 · 187-193

DOI: 10.1016/j.clnesp.2023.01.026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Nutrition ESPEN, 2023-04. Verfasst von Malia N M Blue und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Exercise and Sport Science, The University of North Carolina, Chapel Hill, NC, 27599, USA. Electronic address: mblue@unc.edu. Hauptthemen laut MEDLINE: Body Water, Ethnicity. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND & AIMS: Total body water (TBW) is the largest component of fat free mass and therefore is commonly used in multi-compartment body composition models and as a stand-alone method to assess body composition. Previous literature has not validated bioelectrical impedance spectroscopy device estimates of TBW in racial and ethnic minority populations; previous studies have focused on bioelectrical impedance analysis devices that rely on proprietary algorithms and participant characteristics for accuracy. The purpose of this study was to assess the validity of two bioelectrical impedance spectroscopy devices for measures of TBW compared to a deuterium dilution criterion in a multi-ethnic sample. METHODS: 109 individuals (55% female, Age: 26.6 ± 6.9 yrs, BMI: 25.3 ± 4.0 kg/m2) identifying as Asian, African American/Black, Caucasian/White, Hispanic, and Multi-racial were enrolled. After a 12 h fast, participants provided a saliva sample for the criterion baseline TBW measure and completed two bioelectrical impedance device (BIS, IB) measurements of TBW. Participants then ingested deuterium oxide (D2O). After an equilibration period, participants provided a second saliva sample for analysis of TBW. RESULTS: For the total multi-ethnic sample, BIS estimates demonstrated good to fairly good agreement (Total error [TE] = 2.56 L, R2 = 0.951) and IB estimates were excellent to very good (TE = 1.95 L, R2 = 0.975). Validity results did not vary meaningfully between race and ethnicity. CONCLUSIONS: The results suggest the BIS and IB devices evaluated can produce valid TBW estimates compared to D2O in a multi-ethnic sample. TBW estimates from the IB may have better agreement with D2O compared to the BIS when using the default settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Body WaterEthnicityHumansFemaleYoung AdultAdultMaleElectric ImpedanceMinority GroupsBody Composition

Stichwörter der Autor:innen

AgreementBioimpedanceBody compositionDeuterium oxideEthnicityRacial groups

Autor:innen und Institutionen

  • Department of Exercise and Sport Science, The University of North Carolina, Chapel Hill, NC, 27599, USA. Electronic address: mblue@unc.edu.
  • Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, 79409, USA.
  • Department of Exercise Science, University of South Carolina, Columbia, SC, 29208, USA.
  • Department of Exercise and Sport Science, The University of North Carolina, Chapel Hill, NC, 27599, USA.
  • Emerging Growth and Incubation Group, Intel Corporation, Santa Clara, CA, USA.
  • Department of Exercise and Sport Science, The University of North Carolina, Chapel Hill, NC, 27599, USA; Department of Nutrition, The University of North Carolina, Chapel Hill, NC, 27599, USA.

Zitieren

APA

Blue, M. N. M., Tinsley, G. M., Hirsch, K. R., Ryan, E. D., Ng, B. K., & Smith-Ryan, A. E. (2023). Validity of total body water measured by multi-frequency bioelectrical impedance devices in a multi-ethnic sample. Clinical Nutrition ESPEN, 54, 187-193. https://doi.org/10.1016/j.clnesp.2023.01.026

Vancouver

Blue MNM, Tinsley GM, Hirsch KR, Ryan ED, Ng BK, Smith-Ryan AE. Validity of total body water measured by multi-frequency bioelectrical impedance devices in a multi-ethnic sample. Clinical Nutrition ESPEN. 2023;54:187-193. doi:10.1016/j.clnesp.2023.01.026

BibTeX
@article{Blue2023,
  author = {Blue, Malia N M and Tinsley, Grant M and Hirsch, Katie R and Ryan, Eric D and Ng, Bennett K and Smith-Ryan, Abbie E},
  title = {Validity of total body water measured by multi-frequency bioelectrical impedance devices in a multi-ethnic sample},
  journal = {Clinical Nutrition ESPEN},
  year = {2023},
  volume = {54},
  pages = {187--193},
  doi = {10.1016/j.clnesp.2023.01.026}
}
Kostenlos starten →