Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 23.10.2023. Verfasst von Guillaume Fahrni und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Cardiothoracic and Vascular Division, Lausanne University Hospital and University of Lausanne,…. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
To evaluate a reduced iodine volume protocol for lower extremity CT angiography (CTA) using dual-energy CT (DECT).
Methods
This retrospective study included consecutive patients who underwent lower extremity CTA from June to December 2022. A 10 ml 1:1 mixed test bolus was performed, followed by a 40 ml full bolus at a 2.5/s injection rate, using 400 mg/ml iodine contrast media. Conventional and 40 keV virtual monoenergetic images (VMI) were reconstructed. For both reconstructions, five main artery segments were assessed with a 3-point image quality score as well as quantitative attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements with diagnostic quality thresholds (respectively >150 HU and >3).
Results
Forty patients were included in the study (mean age 68 ± 12 yo). 200 artery segments were assessed. Median qualitative image scores were 3 [IQR, 3, 3] for both reconstructions. 40 keV VMI upgraded qualitative scores for 51 (26%) of patients, including 9 (5%) from nondiagnostic to diagnostic quality. 40 keV VMI obtained attenuation and CNR diagnostic quality for respectively 100% and 100% of segments, compared with 96% and 98% for conventional images ( p < 0.001). Distal artery segments showed the most differences between 40 keV VMI and conventional images.
Conclusion
A low-iodine lower extremity CTA protocol is feasible, with 40 keV virtual monoenergetic spectral reconstruction enabling maintained diagnostic image quality at the distal artery segments.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, Cardiothoracic and Vascular Division, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Villeurbanne, France.
- Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, Bron, France.
Zitieren
APA
Fahrni, G., Mingas, T., Deliessche, A., Hraichi, S., Rotzinger, D. C., Si-Mohamed, S. A., Boccalini, S., & Douek, P. (2023). Low-iodine 40-keV virtual monoenergetic CT angiography of the lower extremities. Frontiers in Cardiovascular Medicine, 10. https://doi.org/10.3389/fcvm.2023.1276738
Vancouver
Fahrni G, Mingas T, Deliessche A, Hraichi S, Rotzinger DC, Si-Mohamed SA, et al. Low-iodine 40-keV virtual monoenergetic CT angiography of the lower extremities. Frontiers in Cardiovascular Medicine. 2023;10. doi:10.3389/fcvm.2023.1276738
BibTeX
@article{Fahrni2023,
author = {Fahrni, Guillaume and Mingas, Thomas and Deliessche, Arthur and Hraichi, Smail and Rotzinger, David C and Si-Mohamed, Salim A and Boccalini, Sara and Douek, Philippe},
title = {Low-iodine 40-keV virtual monoenergetic CT angiography of the lower extremities},
journal = {Frontiers in Cardiovascular Medicine},
year = {2023},
volume = {10},
doi = {10.3389/fcvm.2023.1276738}
}
EUVIMED