EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Virtual Monoenergetic Imaging of Lower Extremities Using Dual-Energy CT Angiography in Patients with Diabetes Mellitus

Giuseppe Mauro Bucolo iD, Tommaso D'Angelo iD, Ibrahim Yel iD, Vitali Koch iD, Leon D Gruenewald iD, Ahmed E Othman iD, Leona Soraja Alizadeh, Daniel P Overhoff iD, Stephan Waldeck, Simon S Martin, Silvio Mazziotti, Giorgio Ascenti und 3 weitere

Diagnostics · 18.05.2023 · 13 (10) · 1790

DOI: 10.3390/diagnostics13101790 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 18.05.2023. Verfasst von Giuseppe Mauro Bucolo und 14 weiteren Autor:innen. Beteiligte Einrichtung: Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germ…. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Type 2 diabetes mellitus (DM) is the most common metabolic disorder in the world and an important risk factor for peripheral arterial disease (PAD). CT angiography represents the method of choice for the diagnosis, pre-operative planning, and follow-up of vascular disease. Low-energy dual-energy CT (DECT) virtual mono-energetic imaging (VMI) has been shown to improve image contrast, iodine signal, and may also lead to a reduction in contrast medium dose. In recent years, VMI has been improved with the use of a new algorithm called VMI+, able to obtain the best image contrast with the least possible image noise in low-keV reconstructions.

Purpose

To evaluate the impact of VMI+ DECT reconstructions on quantitative and qualitative image quality in the evaluation of the lower extremity runoff. Materials and Methods: We evaluated DECT angiography of lower extremities in patients suffering from diabetes who had undergone clinically indicated DECT examinations between January 2018 and January 2023. Images were reconstructed with standard linear blending (F_0.5) and low VMI+ series were generated from 40 to 100 keV, in an interval of 15 keV. Vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for objective analysis. Subjective analysis was performed using five-point scales to evaluate image quality, image noise, and diagnostic assessability of vessel contrast.

Results

Our final study cohort consisted of 77 patients (41 males). Attenuation values, CNR, and SNR were higher in 40-keV VMI+ reconstructions compared to the remaining VMI+ and standard F_0.5 series (HU: 1180.41 ± 45.09; SNR: 29.91 ± 0.99; CNR: 28.60 ± 1.03 vs. HU 251.32 ± 7.13; SNR: 13.22 ± 0.44; CNR: 10.57 ± 0.39 in standard F_0.5 series) (p < 0.0001). Subjective image rating was significantly higher in 55-keV VMI+ images compared to the other VMI+ and standard F_0.5 series in terms of image quality (mean score: 4.77), image noise (mean score: 4.39), and assessability of vessel contrast (mean value: 4.57) (p < 0.001).

Conclusions

DECT 40-keV and 55-keV VMI+ showed the highest objective and subjective parameters of image quality, respectively. These specific energy levels for VMI+ reconstructions could be recommended in clinical practice, providing high-quality images with greater diagnostic suitability for the evaluation of lower extremity runoff, and potentially needing a lower amount of contrast medium, which is particularly advantageous for diabetic patients.

Schlagwörter

Stichwörter der Autor:innen

CT angiographydual energylower extremitiesvirtual monoenergetic imaging

Autor:innen und Institutionen

  • Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany.
  • Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, 98122 Messina, Italy.
  • Department of Radiology and Nuclear Medicine, Erasmus MC, 3015 GD Rotterdam, The Netherlands.
  • Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60596 Frankfurt am Main, Germany.
  • Department of Neuroradiology, University Hospital Mainz, 55131 Mainz, Germany.
  • Department of Diagnostic and Interventional Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, 56072 Koblenz, Germany.

ORCID-Profile: Giuseppe Mauro Bucolo, Tommaso D'Angelo, Ibrahim Yel, Vitali Koch, Leon D Gruenewald, Ahmed E Othman, Daniel P Overhoff, Thomas J Vogl

Zitieren

APA

Bucolo, G. M., D'Angelo, T., Yel, I., Koch, V., Gruenewald, L. D., Othman, A. E., Alizadeh, L. S., Overhoff, D. P., Waldeck, S., Martin, S. S., Mazziotti, S., Ascenti, G., Blandino, A., Vogl, T. J., & Booz, C. (2023). Virtual Monoenergetic Imaging of Lower Extremities Using Dual-Energy CT Angiography in Patients with Diabetes Mellitus. Diagnostics, 13(10), 1790. https://doi.org/10.3390/diagnostics13101790

Vancouver

Bucolo GM, D'Angelo T, Yel I, Koch V, Gruenewald LD, Othman AE, et al. Virtual Monoenergetic Imaging of Lower Extremities Using Dual-Energy CT Angiography in Patients with Diabetes Mellitus. Diagnostics. 2023;13(10):1790. doi:10.3390/diagnostics13101790

BibTeX
@article{Bucolo2023,
  author = {Bucolo, Giuseppe Mauro and D'Angelo, Tommaso and Yel, Ibrahim and Koch, Vitali and Gruenewald, Leon D and Othman, Ahmed E and Alizadeh, Leona Soraja and Overhoff, Daniel P and Waldeck, Stephan and Martin, Simon S and Mazziotti, Silvio and Ascenti, Giorgio and Blandino, Alfredo and Vogl, Thomas J and Booz, Christian},
  title = {Virtual Monoenergetic Imaging of Lower Extremities Using Dual-Energy CT Angiography in Patients with Diabetes Mellitus},
  journal = {Diagnostics},
  year = {2023},
  volume = {13},
  number = {10},
  pages = {1790},
  doi = {10.3390/diagnostics13101790}
}
Kostenlos starten →