EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Finite element and in vitro biomechanical analysis of a novel magnesium degradation-induced variable fixation plate

Jian Wen, Xingyu Wang, Zhe Wang, Yu Zeng, Xiaofan Chen, Xueqi Liu, Xieping Dong

Frontiers in Bioengineering and Biotechnology · 02.03.2026 · 14

DOI: 10.3389/fbioe.2026.1774985 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 02.03.2026. Verfasst von Jian Wen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pain Management, The 2nd Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, China. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnesium degradation-induced variable fixation plates (MVFPs) offer different fixation modes during fracture healing, but their biomechanical reliability is not well established. Materials and Methods CT images of femurs from volunteers were used to build a model, and Abaqus software simulated deformation, stress, and relative displacement under various stress conditions. Mechanical tests including vertical loading, four-point bending, torsion, and fatigue were conducted using femur simulation models and suitable magnesium shims were screened.

Results

Finite element analysis showed that under 700N vertical loading, MVFP exhibited 83%–116% of the total deformation, 88%–120% of the maximum stress, and 86%–121% of the average relative displacement compared to locking plate (LP). Under 250N four-point bending, these were 76%–186%, 73%–183%, and 61%–170%, respectively. Under 10Nm torsional moment, they were 102%–109%, 114%–118% (for implants), and 110%–113%, respectively. In vitro biomechanical tests showed that MVFP had greater total and relative displacements but lower axial, four-point bending, and torsional stiffness (81.5%, 68.5%, and 63.9% of LP, respectively). Fatigue testing indicated both LP and MVFP samples endured 100,000 cycles of 700N vertical load without failure. The MVFP with a 0.5 mm shim exhibited superior stiffness and offered greater space for elastic deformation compared to the 1 mm shim.

Conclusion

Although MVFP’s stiffness slightly decreases compared to LP after shim degradation, it improves interfragmentary micromotion and reduces stress shielding while maintaining good fatigue resistance. MVFP with 0.5 mm axial micromotion shows promise for further development and clinical application.

Schlagwörter

Stichwörter der Autor:innen

biomechanicalfinite element analysismagnesiummicromotionvariable fixation plate

Autor:innen und Institutionen

  • Department of Pain Management, The 2nd Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, China.
  • Department of Orthopedics, Jiangxi Province Hospital of Integrated Chinese and Western Medicine, Nanchang, Jiangxi, China.
  • JXHC Key Laboratory of Digital Orthopedics, Jiangxi Provincial People's Hospital, The First Affiliated Hospital of Nanchang Medical College, Nanchang, Jiangxi, China.
  • Department of Orthopedics, People's Hospital of Ningxia Hui Autonomous Region, Third Clinical Medical College of Ningxia Medical University, Ningxia Medical University, Yinchuan, China.

Zitieren

APA

Wen, J., Wang, X., Wang, Z., Zeng, Y., Chen, X., Liu, X., & Dong, X. (2026). Finite element and in vitro biomechanical analysis of a novel magnesium degradation-induced variable fixation plate. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1774985

Vancouver

Wen J, Wang X, Wang Z, Zeng Y, Chen X, Liu X, et al. Finite element and in vitro biomechanical analysis of a novel magnesium degradation-induced variable fixation plate. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1774985

BibTeX
@article{Wen2026,
  author = {Wen, Jian and Wang, Xingyu and Wang, Zhe and Zeng, Yu and Chen, Xiaofan and Liu, Xueqi and Dong, Xieping},
  title = {Finite element and in vitro biomechanical analysis of a novel magnesium degradation-induced variable fixation plate},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2026},
  volume = {14},
  doi = {10.3389/fbioe.2026.1774985}
}
Kostenlos starten →