Fachartikel in der Zeitschrift Orthopaedic Surgery, online erschienen am 19.12.2024. Verfasst von Weipeng Lin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Yunfu People's Hospital, Yunfu, China. Hauptthemen laut MEDLINE: Bone Screws, Joint Instability, Atlanto-Occipital Joint, Cranial Fossa, Posterior. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Guangdong Medical Research Foundation, Research Foundation of YunFu People's Hospital, National Natural Science Foundation of China.
Abstract (Originalsprache)
Objective
The clivus is trapezoidal in shape with uneven bone structure, the optimal number and position of screws for clival fixation are not clear. Therefore, this study aims to explore the optimization clival screw fixation method for occipitocervical instability using finite element analysis.
Methods
Seven finite element models were developed to evaluate biomechanical properties of clival screw fixation for treating occipitocervical stability, including (i) one clival screw fixation A1 and A2 models; (ii) two clival screws fixation B1 and B2 models; (iii) three clival screws fixation C1 and C2 models; (iv) four clival screws fixation D1 model. Loads of 1.5 Nm were applied to the model fRoM different directions to induce flexion, extension, lateral bending, and axial rotation movements.
Results
The regular triangle C1 type three clival screws fixation exhibited great stability, with RoM of 4.20° in flexion, 5.80° in extension, 0.85° in lateral bending, and 1.60° in axial rotation. The peak stress on the internal fixation devices were relatively low, with maximum screw stress of 194 MPa in flexion, 276 MPa in extension, 180 MPa in lateral bending, and 213 MPa in axial rotation; the maximum plate stress were 126, 554, 426, and 378 MPa, respectively. The areas with higher stress were mainly concentrated at the robust neck section of the plate.
Conclusion
The triangular configuration of three clival screws fixation represented the optimized anterior occipitocervical fixation method through the clivus, offering superior biomechanical stability, lower stress on the devices and dispersed stress distribution in the occipitocervical region.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Yunfu People's Hospital, Yunfu, China.
- Division of Spinal Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
- Department of Anatomy, Southern Medical University, Guangzhou, China.
Förderung
- Guangdong Medical Research Foundation
- Research Foundation of YunFu People's Hospital
- National Natural Science Foundation of China
- Natural Science Foundation of Guangdong Province
Zitieren
APA
Lin, W., Zheng, J., Zhang, M., Xu, P., Xiao, H., & Ji, W. (2025). Biomechanical Evaluation of Clival Screw Fixation for Occipitocervical Instablity: A Finite Element Analysis. Orthopaedic Surgery, 17(2), 583-592. https://doi.org/10.1111/os.14314
Vancouver
Lin W, Zheng J, Zhang M, Xu P, Xiao H, Ji W. Biomechanical Evaluation of Clival Screw Fixation for Occipitocervical Instablity: A Finite Element Analysis. Orthopaedic Surgery. 2025;17(2):583-592. doi:10.1111/os.14314
BibTeX
@article{Lin2025,
author = {Lin, Weipeng and Zheng, Jianying and Zhang, Meichao and Xu, Panjie and Xiao, Hang and Ji, Wei},
title = {Biomechanical Evaluation of Clival Screw Fixation for Occipitocervical Instablity: A Finite Element Analysis},
journal = {Orthopaedic Surgery},
year = {2025},
volume = {17},
number = {2},
pages = {583--592},
doi = {10.1111/os.14314}
}
EUVIMED