Biomechanical stability of magnesium plate and screw fixation systems in LeFort I osteotomy: a three-dimensional finite element analysis
Maxillofacial Plastic and Reconstructive Surgery · 18.12.2024 · 46 (1)
DOI: 10.1186/s40902-024-00451-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Maxillofacial Plastic and Reconstructive Surgery, online erschienen am 18.12.2024. Verfasst von Su-Min Cho und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Hallym University Sacred Heart Hospital, Anyang, 14066, Republic of Korea. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Titanium (Ti–6Al–4 V) is used for fixation in LeFort I osteotomy, a procedure for treating midface deformities. This study assessed the biomechanical stabilities of two Mg alloys (WE43 and ZK60) as biodegradable alternatives and compared them against Ti using finite element analyses. The LeFort I osteotomy procedure was simulated, and various plate and screw configurations were tested. The maximum principal and peak von Mises stresses in the metal plates and bone screws were measured under four load conditions, and the stability was evaluated.
Results
The holes in the Mg screws, as compared with the Ti counterparts, exhibited higher and lower stress levels in the cortical and cancellous bones, respectively. The Mg screws also exhibited a higher fracture risk. The ZK60 plate, as compared with the Ti and WE43 plates, exhibited a lower fracture risk under all load conditions. ZK60 exhibited higher biomechanical stability in terms of maintaining the gap between osteotomy surfaces and lower fracture risk; the osteotomy surfaces with Ti im-plants underwent bone impaction, resulting in gap closure.
Conclusions
Although the Mg implants exhibited better stress distribution, their screw strength requires improvement. Appropriate improvements can promote the use of Mg alloys in bone fixation applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, Hallym University Sacred Heart Hospital, Anyang, 14066, Republic of Korea.
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon, 24252, Republic of Korea.
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang, 14066, Republic of Korea.
- Dental Life Science Research Institute/Innovation Research & Support Center for Dental Science, Seoul National University Dental Hospital, Seoul, 03080, Republic of Korea.
- Institute of Clinical Dentistry, Hallym University, Chuncheon, 24252, Republic of Korea.
- Department of Oral and Maxillofacial Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, 18450, Republic of Korea.
Zitieren
APA
Cho, S. M., Yang, B. E., Kim, W. H., Park, S. Y., On, S. W., Lee, J. H., & Byun, S. H. (2024). Biomechanical stability of magnesium plate and screw fixation systems in LeFort I osteotomy: a three-dimensional finite element analysis. Maxillofacial Plastic and Reconstructive Surgery, 46(1). https://doi.org/10.1186/s40902-024-00451-8
Vancouver
Cho SM, Yang BE, Kim WH, Park SY, On SW, Lee JH, et al. Biomechanical stability of magnesium plate and screw fixation systems in LeFort I osteotomy: a three-dimensional finite element analysis. Maxillofacial Plastic and Reconstructive Surgery. 2024;46(1). doi:10.1186/s40902-024-00451-8
BibTeX
@article{Cho2024,
author = {Cho, Su-Min and Yang, Byoung-Eun and Kim, Won-Hyeon and Park, Sang-Yoon and On, Sung-Woon and Lee, Jong-Ho and Byun, Soo-Hwan},
title = {Biomechanical stability of magnesium plate and screw fixation systems in LeFort I osteotomy: a three-dimensional finite element analysis},
journal = {Maxillofacial Plastic and Reconstructive Surgery},
year = {2024},
volume = {46},
number = {1},
doi = {10.1186/s40902-024-00451-8}
}
EUVIMED