Custom 3D-printed split-type triflange implants for severe acetabular defects: mid-term clinical outcomes and biomechanical insights from finite element analysis
Frontiers in Bioengineering and Biotechnology · 26.11.2025 · 13
DOI: 10.3389/fbioe.2025.1702276 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 26.11.2025. Verfasst von Yu Guo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing …. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Paprosky 3B acetabular defects challenge revision total hip arthroplasty (THA) due to conventional techniques’ high failure rates. This study evaluates midterm outcomes and biomechanical performance of 3D-printed split-type triflange acetabular cups for Paprosky 3B defects. Materials and methods From 02/01/2017 to 10/30/2021, we retrospectively assessed 14 patients with Paprosky 3B defects using 3D-printed split-type triflange cups. Preoperative CT-based 3D models guided implant design with porous surfaces and optimized screw fixation. Clinical outcomes were assessed via Harris Hip Score (HHS) and Oxford Hip Score (OHS). Radiographic parameters and implant stability were analyzed. Biomechanical characteristics were evaluated through finite element analysis (FEA) under physiological loads representing single-leg stance, walking, and jogging (700N, 2800N, and 4200N).
Results
At mean 74.2-month follow-up, HHS improved from 31.9 ± 8.5 to 82.9 ± 5.9 (p < 0.05) and OHS from 7.6 ± 2.3 to 35.4 ± 3.1 (p < 0.05). Anatomical hip center restoration was achieved with comparable postoperative and contralateral rotation center measurements. Radiographic analysis confirmed stable fixation in all cases without loosening. FEA revealed distinct biomechanical behavior between bone models. In both normal and osteoporotic models, stress concentrated at the superior flange screw fixation site and the superior acetabular rim. Under 700N loading, interfacial micromotion at all measurement points (P1-P3) remained below the 40 μm threshold for osseointegration. However, at higher loads (2800N and 4200N), P1 micromotion significantly exceeded this critical threshold in both models, reaching 122.861 μm and 131.244 μm respectively at maximum loading, while P2 and P3 maintained acceptable levels.
Conclusion
Custom 3D-printed split-type triflange prostheses achieve excellent midterm functional restoration and biomechanical stability in Paprosky 3B defects. Key advantages include precise hip rotation center reconstruction, favorable stress distribution, and reduced intraoperative morbidity. Early partial weight-bearing is safe, though high-impact activities should await radiographic confirmation of osseointegration. Long-term validation of durability is warranted.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Wuxi, China.
Zitieren
APA
Guo, Y., Feng, D., Gu, X., Wang, L., Ding, Y., Liu, Y., & Qin, J. (2025). Custom 3D-printed split-type triflange implants for severe acetabular defects: mid-term clinical outcomes and biomechanical insights from finite element analysis. Frontiers in Bioengineering and Biotechnology, 13. https://doi.org/10.3389/fbioe.2025.1702276
Vancouver
Guo Y, Feng D, Gu X, Wang L, Ding Y, Liu Y, et al. Custom 3D-printed split-type triflange implants for severe acetabular defects: mid-term clinical outcomes and biomechanical insights from finite element analysis. Frontiers in Bioengineering and Biotechnology. 2025;13. doi:10.3389/fbioe.2025.1702276
BibTeX
@article{Guo2025,
author = {Guo, Yu and Feng, Dehong and Gu, Xiaofeng and Wang, Ling and Ding, Yujian and Liu, Yi and Qin, Jialin},
title = {Custom 3D-printed split-type triflange implants for severe acetabular defects: mid-term clinical outcomes and biomechanical insights from finite element analysis},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2025},
volume = {13},
doi = {10.3389/fbioe.2025.1702276}
}
EUVIMED