Hip revision arthroplasty for severe acetabular defects using custom 3D-printed porous titanium implants: Minimum 2-year follow-up
Journal of Orthopaedic Surgery · 2026-05 · 34 (2)
DOI: 10.1177/10225536261475369 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedic Surgery, online erschienen am 30.07.2026. Verfasst von Stanislav Bondarenko und 4 weiteren Autor:innen. Beteiligte Einrichtung: Sytenko Institute of Spine and Joint Pathology of the National Academy of Medical Sciences of Ukraine, Kharkiv, Ukraine. Hauptthemen laut MEDLINE: Acetabulum, Arthroplasty, Replacement, Hip, Printing, Three-Dimensional, Hip Prosthesis. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose was to evaluate the outcomes of custom 3D-printed trabecular titanium implants for acetabular revision total hip arthroplasty (rTHA) in patients with severe acetabular defects (Paprosky type 2 or 3) at minimum 2-year follow up.
Methods
A prospective analysis was conducted on 10 patients (8 female) undergoing rTHA with custom 3D-printed titanium implants (3D-TTi), manufactured via laser sintering from Ti6Al4V titanium powder. At 1-year follow-up were measured the angles of inclination and anteversion, the vertical (VCOR) and horizontal (HCOR) center of rotation, and leg length difference (LLD). The Harris hip score (HHS) and Oxford hip score (OHS) was used. The mean follow-up period was of 36.4 (range 24.5–48.2) months, ensuring a maximum follow-up at 4 years.
Results
All custom 3D-TTi (100%) in patients were positioned within the Lewinnek safe zone:. The COR was restored in all patients after rTHA. HCOR did not differ from the contralateral limb before and after rTHA. The VCOR was different before surgery, and after rTHA it did not differ due to correction by -6.9 mm. In 9 of 10 patients, the correction of the length of the operated limb did not exceed 4 cm, and the mean LLD after rTHA was 6.3 mm. One patient had a dislocation at 3 weeks. At 1-year follow-up, HHS (24.0±11.4 vs. 93.3±1.6) and OHS (8.1±2.6 vs. 41.3±4.1) were significantly improved (p=0.005).
Conclusion
At a minimum follow-up of 2 years, none of the 3D-printed trabecular titanium implants required revision, indicating promising early implant stability and function in patients with severe acetabular defects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Sytenko Institute of Spine and Joint Pathology of the National Academy of Medical Sciences of Ukraine, Kharkiv, Ukraine.
- Department of trauma, Municipal City Clinical Hospital #16, Dnipro, Ukraine.
- Velta Medical LLC, Dnipro, Ukraine.
- Osteonica LLC, Kyiv, Ukraine.
ORCID-Profile: Valentyna Maltseva
Zitieren
APA
Bondarenko, S., Makarov, V., Pryz, O., Burburska, S., & Maltseva, V. (2026). Hip revision arthroplasty for severe acetabular defects using custom 3D-printed porous titanium implants: Minimum 2-year follow-up. Journal of Orthopaedic Surgery, 34(2). https://doi.org/10.1177/10225536261475369
Vancouver
Bondarenko S, Makarov V, Pryz O, Burburska S, Maltseva V. Hip revision arthroplasty for severe acetabular defects using custom 3D-printed porous titanium implants: Minimum 2-year follow-up. Journal of Orthopaedic Surgery. 2026;34(2). doi:10.1177/10225536261475369
BibTeX
@article{Bondarenko2026,
author = {Bondarenko, Stanislav and Makarov, Vasyl and Pryz, Olena and Burburska, Svitlana and Maltseva, Valentyna},
title = {Hip revision arthroplasty for severe acetabular defects using custom 3D-printed porous titanium implants: Minimum 2-year follow-up},
journal = {Journal of Orthopaedic Surgery},
year = {2026},
volume = {34},
number = {2},
doi = {10.1177/10225536261475369}
}
EUVIMED