EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Prospective Evaluation of Accelerated Brain MRI Using Deep Learning-Based Reconstruction: Simultaneous Application to 2D Spin-Echo and 3D Gradient-Echo Sequences

Kyu Sung Choi iD, Chanrim Park iD, Ji Ye Lee iD, Kyung Hoon Lee iD, Young Hun Jeon iD, Inpyeong Hwang iD, Roh Eul Yoo iD, Tae Jin Yun iD, Mi Ji Lee iD, Keun-Hwa Jung iD, Koung Mi Kang iD

Korean Journal of Radiology · 2025 · 26 (1) · 54

DOI: 10.3348/kjr.2024.0653 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Korean Journal of Radiology, 2025. Verfasst von Kyu Sung Choi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Brain, Imaging, Three-Dimensional. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: SNUH, KMDF, NRF.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To prospectively evaluate the effect of accelerated deep learning-based reconstruction (Accel-DL) on improving brain magnetic resonance imaging (MRI) quality and reducing scan time compared to that in conventional MRI. MATERIALS AND METHODS: This study included 150 participants (51 male; mean age 57.3 ± 16.2 years). Each group of 50 participants was scanned using one of three 3T scanners from three different vendors. Conventional and Accel-DL MRI images were obtained from each participant and compared using 2D T1- and T2-weighted and 3D gradient-echo sequences. Accel-DL acquisition was achieved using optimized scan parameters to reduce the scan time, with the acquired images reconstructed using U-Net-based software to transform low-quality, undersampled k-space data into high-quality images. The scan times of Accel-DL and conventional MRI methods were compared. Four neuroradiologists assessed the overall image quality, structural delineation, and artifacts using Likert scale (5- and 3-point scales). Inter-reader agreement was assessed using Fleiss' kappa coefficient. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and volumetric quantification of regional structures and white matter hyperintensities (WMHs) was performed. RESULTS: Accel-DL showed a mean scan time reduction of 39.4% (range, 24.2%-51.3%). Accel-DL improved overall image quality (3.78 ± 0.71 vs. 3.36 ± 0.61, P < 0.001), structure delineation (2.47 ± 0.61 vs. 2.35 ± 0.62, P < 0.001), and artifacts (3.73 ± 0.72 vs. 3.71 ± 0.69, P = 0.016). Inter-reader agreement was fair to substantial (κ = 0.34-0.50). SNR and CNR increased in Accel-DL (82.0 ± 23.1 vs. 31.4 ± 10.8, P = 0.02; 12.4 ± 4.1 vs. 4.4 ± 11.2, P = 0.02). Bland-Altman plots revealed no significant differences in the volumetric measurements of 98.2% of the relevant regions, except in the deep gray matter, including the thalamus. Five of the six lesion categories showed no significant differences in WMH segmentation, except for leukocortical lesions (r = 0.64 ± 0.29). CONCLUSION: Accel-DL substantially reduced the scan time and improved the quality of brain MRI in both spin-echo and gradient-echo sequences without compromising volumetry, including lesion quantification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningMagnetic Resonance ImagingBrainImaging, Three-DimensionalHumansMaleMiddle AgedProspective StudiesFemaleAdultSignal-To-Noise RatioAgedImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedArtifacts

Stichwörter der Autor:innen

ArtifactsDeep learningImage reconstructionSignal-to-noise ratioVolumetric analysis

Autor:innen und Institutionen

  • Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Department of Neurology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea. we3001@gmail.com.

ORCID-Profile: Kyu Sung Choi, Chanrim Park, Ji Ye Lee, Kyung Hoon Lee, Young Hun Jeon, Inpyeong Hwang, Roh Eul Yoo, Tae Jin Yun, Mi Ji Lee, Keun-Hwa Jung, Koung Mi Kang

Förderung

  • SNUH
  • KMDF
  • NRF
  • AIRS Medical Inc.
  • Korea Medical Device Development Fund
  • National Research Foundation of Korea

Zitieren

APA

Choi, K. S., Park, C., Lee, J. Y., Lee, K. H., Jeon, Y. H., Hwang, I., Yoo, R. E., Yun, T. J., Lee, M. J., Jung, K. H., & Kang, K. M. (2025). Prospective Evaluation of Accelerated Brain MRI Using Deep Learning-Based Reconstruction: Simultaneous Application to 2D Spin-Echo and 3D Gradient-Echo Sequences. Korean Journal of Radiology, 26(1), 54. https://doi.org/10.3348/kjr.2024.0653

Vancouver

Choi KS, Park C, Lee JY, Lee KH, Jeon YH, Hwang I, et al. Prospective Evaluation of Accelerated Brain MRI Using Deep Learning-Based Reconstruction: Simultaneous Application to 2D Spin-Echo and 3D Gradient-Echo Sequences. Korean Journal of Radiology. 2025;26(1):54. doi:10.3348/kjr.2024.0653

BibTeX
@article{Choi2025,
  author = {Choi, Kyu Sung and Park, Chanrim and Lee, Ji Ye and Lee, Kyung Hoon and Jeon, Young Hun and Hwang, Inpyeong and Yoo, Roh Eul and Yun, Tae Jin and Lee, Mi Ji and Jung, Keun-Hwa and Kang, Koung Mi},
  title = {Prospective Evaluation of Accelerated Brain MRI Using Deep Learning-Based Reconstruction: Simultaneous Application to 2D Spin-Echo and 3D Gradient-Echo Sequences},
  journal = {Korean Journal of Radiology},
  year = {2025},
  volume = {26},
  number = {1},
  pages = {54},
  doi = {10.3348/kjr.2024.0653}
}
Kostenlos starten →