EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

Jae-Chan Ryu iD, Jong-Tae Yoon iD, Byung Jun Kim iD, Mi Hyeon Kim iD, Eun Ji Moon iD, Pae Sun Suh iD, Yun Hwa Roh iD, Hye Hyeon Moon iD, Boseong Kwon iD, Deok Hee Lee iD, Yunsun Song iD

Korean Journal of Radiology · 2023

DOI: 10.3348/kjr.2023.0169 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Korean Journal of Radiology, 2023. Verfasst von Jae-Chan Ryu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Lens, Crystalline. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. MATERIALS AND METHODS: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. RESULTS: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm², P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. CONCLUSION: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intracranial AneurysmLens, CrystallineHumansProspective StudiesRadiation DosageCerebral AngiographyPhantoms, Imaging

Stichwörter der Autor:innen

3-dimensional rotational angiographyCerebral angiographyDose reductionHead off-centeringLens radiation dose

Autor:innen und Institutionen

  • Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, Seoul, Korea.
  • Advanced Therapies, Siemens Healthineers Ltd., Seoul, Korea.
  • Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. songsongggg@gmail.com.

ORCID-Profile: Jae-Chan Ryu, Jong-Tae Yoon, Byung Jun Kim, Mi Hyeon Kim, Eun Ji Moon, Pae Sun Suh, Yun Hwa Roh, Hye Hyeon Moon, Boseong Kwon, Deok Hee Lee, Yunsun Song

Zitieren

APA

Ryu, J. C., Yoon, J. T., Kim, B. J., Kim, M. H., Moon, E. J., Suh, P. S., Roh, Y. H., Moon, H. H., Kwon, B., Lee, D. H., & Song, Y. (2023). Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study. Korean Journal of Radiology. https://doi.org/10.3348/kjr.2023.0169

Vancouver

Ryu JC, Yoon JT, Kim BJ, Kim MH, Moon EJ, Suh PS, et al. Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study. Korean Journal of Radiology. 2023. doi:10.3348/kjr.2023.0169

BibTeX
@article{Ryu2023,
  author = {Ryu, Jae-Chan and Yoon, Jong-Tae and Kim, Byung Jun and Kim, Mi Hyeon and Moon, Eun Ji and Suh, Pae Sun and Roh, Yun Hwa and Moon, Hye Hyeon and Kwon, Boseong and Lee, Deok Hee and Song, Yunsun},
  title = {Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study},
  journal = {Korean Journal of Radiology},
  year = {2023},
  doi = {10.3348/kjr.2023.0169}
}
Kostenlos starten →