Factors associated with increased patient radiation dose during cerebral aneurysm embolization
Radiation Protection Dosimetry · 11.08.2026 · 202 (13) · 1057-1068
DOI: 10.1093/rpd/ncag044 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 06.05.2026. Verfasst von Satoru Kawauchi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku Tokyo 105-8470, Japan. Hauptthemen laut MEDLINE: Radiation Dosage, Intracranial Aneurysm, Embolization, Therapeutic, Radiation Exposure. Die Arbeit nennt 63 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
With expanding indications for interventional neuroradiology, patient radiation exposure remains a significant concern. This study aimed to identify predictors of high peak skin dose and left lens doses using directly measured patient radiation data. We retrospectively analyzed patient doses and performed multivariate logistic regression. Treatment of a posterior circulation aneurysm [odds ratio (OR) = 7.491; 95% confidence interval (CI), 1.217–46.110] and stent use (OR = 5.516; 95% CI, 1.318–23.085) were identified as independent predictors of peak skin dose exceeding 1.0 Gy. Stent use was also a significant predictor of left lens dose exceeding 100 mGy (OR = 3.141; 95% CI, 1.488–7.851). These findings provide a robust, evidence-based framework for identifying high-risk patients preprocedurally. This knowledge is crucial for enhancing the informed consent process and justifying the timely implementation of dose-reduction strategies to minimize the risk of radiation-induced injuries.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku Tokyo 105-8470, Japan.
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai, Miyagi 980-8575, Japan.
- Okinaka Memorial Institute for Medical Research, 2-2-2 Toranomon, Minato-ku, Tokyo 105-8470, Japan.
- Department of Radiation Regulatory Science Research, National Institute of Radiological Sciences, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba 263-8555, Japan.
- Department of Endovascular Neurosurgery, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo 105-8470, Japan.
ORCID-Profile: Satoru Kawauchi, Koichi Chida, Takashi Moritake
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Kawauchi, S., Chida, K., Moritake, T., Hamada, Y., & Tsuruta, W. (2026). Factors associated with increased patient radiation dose during cerebral aneurysm embolization. Radiation Protection Dosimetry, 202(13), 1057-1068. https://doi.org/10.1093/rpd/ncag044
Vancouver
Kawauchi S, Chida K, Moritake T, Hamada Y, Tsuruta W. Factors associated with increased patient radiation dose during cerebral aneurysm embolization. Radiation Protection Dosimetry. 2026;202(13):1057-1068. doi:10.1093/rpd/ncag044
BibTeX
@article{Kawauchi2026,
author = {Kawauchi, Satoru and Chida, Koichi and Moritake, Takashi and Hamada, Yusuke and Tsuruta, Wataro},
title = {Factors associated with increased patient radiation dose during cerebral aneurysm embolization},
journal = {Radiation Protection Dosimetry},
year = {2026},
volume = {202},
number = {13},
pages = {1057--1068},
doi = {10.1093/rpd/ncag044}
}
EUVIMED