EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Predictive Correction Model for Corneal Back Surface Astigmatism With IOLMaster700 Keratometry Data in a Cataractous Population

Achim Langenbucher iD, Peter Hoffmann, Alan Cayless, Nóra Szentmáry, Kamran Riaz iD, Damien Gatinel, Oliver Findl, Seth Pantanelli iD, Tun Kuan Yeo, Giacomo Savini, Jascha Wendelstein iD

Clinical & Experimental Ophthalmology · 2026

DOI: 10.1111/ceo.70009 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Clinical & Experimental Ophthalmology, 2026. Verfasst von Achim Langenbucher und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental Ophthalmology, Saarland University, Homburg (Saar), Germany. Hauptthemen laut MEDLINE: Astigmatism, Cornea, Corneal Topography, Cataract. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fondazione Roma, Italian Ministry of Health, Ministero della Salute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To develop and validate various models to predict total keratometry ( TK ) power vector components TKC0 and TKC45 from classical keratometry (K) KC0 and KC45 based on a large dataset of pre cataract surgery IOLMaster 700 measurements.

Methods

Retrospective cross‐sectional multicentric study evaluating a dataset containing 13 6378 IOLMaster 700 measurements including K and TK . Left eyes were mirrored about the facial axis. Based on 80% training data, we developed a global and segmented constant model ( CM and CMS ), a global and segmented (according to the angle A1 of the flat keratometric meridian) linear model ( LM and LMS ), a harmonic model ( HM ) and compared these to a classical constant ( CMR ) and linear models ( LMR ) segmented into with‐the‐rule, against‐the‐rule and oblique astigmatism. The performance was cross‐validated using the root‐mean‐squared model fit error ( RMSE ).

Results

In the 20% test data, RMSE was 0.173 D before correction and was reduced by 40%–42% to 0.100 and 0.104 D with the correction models. The segmented models performed slightly better than the global models, and the linear models performed slightly better than the constant models. With the individually adjusted changepoints, the CMS and LMS performed slightly better than the reference models CMR and LMR. There was no systematic difference between the RMSE with training and test data, indicating no overfit of the models.

Conclusion

As the performance is quite similar for all tested correction models, we recommend using a simple global constant model to predict TK vector components. This could easily be implemented in any consumer software.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AstigmatismCorneaCorneal TopographyCataractHumansRetrospective StudiesCross-Sectional StudiesMaleFemaleAgedMiddle AgedRefraction, OcularReproducibility of ResultsAged, 80 and over

Stichwörter der Autor:innen

cross‐validationkeratometryprediction of total corneal powerpredictive correction modeltotal keratometry

Autor:innen und Institutionen

  • Department of Experimental Ophthalmology, Saarland University, Homburg (Saar), Germany.
  • Augen-und Laserklinik Castrop-Rauxel, Castrop-Rauxel, Germany.
  • School of Physical Sciences, The Open University, Milton Keynes, UK.
  • Dean McGee Eye Institute, University of Oklahoma, Oklahoma City, Oklahoma, USA.
  • Rothschild Foundation Hospital, Paris, France.
  • Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital, Vienna, Austria.

ORCID-Profile: Achim Langenbucher, Kamran Riaz, Seth Pantanelli, Jascha Wendelstein

Förderung

  • Fondazione Roma
  • Italian Ministry of Health
  • Ministero della Salute

Zitieren

APA

Langenbucher, A., Hoffmann, P., Cayless, A., Szentmáry, N., Riaz, K., Gatinel, D., Findl, O., Pantanelli, S., Yeo, T. K., Savini, G., & Wendelstein, J. (2026). Predictive Correction Model for Corneal Back Surface Astigmatism With IOLMaster700 Keratometry Data in a Cataractous Population. Clinical & Experimental Ophthalmology. https://doi.org/10.1111/ceo.70009

Vancouver

Langenbucher A, Hoffmann P, Cayless A, Szentmáry N, Riaz K, Gatinel D, et al. Predictive Correction Model for Corneal Back Surface Astigmatism With IOLMaster700 Keratometry Data in a Cataractous Population. Clinical & Experimental Ophthalmology. 2026. doi:10.1111/ceo.70009

BibTeX
@article{Langenbucher2026,
  author = {Langenbucher, Achim and Hoffmann, Peter and Cayless, Alan and Szentmáry, Nóra and Riaz, Kamran and Gatinel, Damien and Findl, Oliver and Pantanelli, Seth and Yeo, Tun Kuan and Savini, Giacomo and Wendelstein, Jascha},
  title = {Predictive Correction Model for Corneal Back Surface Astigmatism With IOLMaster700 Keratometry Data in a Cataractous Population},
  journal = {Clinical & Experimental Ophthalmology},
  year = {2026},
  doi = {10.1111/ceo.70009}
}
Kostenlos starten →