One-year Outcomes of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Combined with Cataract Surgery in the Korean Population
Korean Journal of Ophthalmology · 2024
DOI: 10.3341/kjo.2023.0101 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Korean Journal of Ophthalmology, 2024. Verfasst von Minjeong Ashley Koo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea. Hauptthemen laut MEDLINE: Corneal Transplantation, Cataract, Descemet Stripping Endothelial Keratoplasty, Fuchs' Endothelial Dystrophy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
To evaluate the refractive outcomes after ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) combined with phacoemulsification and intraocular lens implantation (triple procedure) in the South Korean population.
Methods
This retrospective observational study included 37 eyes of 36 patients who underwent the UT-DSAEK triple procedure between 2012 and 2021 in a single tertiary hospital. Preoperative and postoperative refractive outcomes and endothelial parameters at 1, 3, 6, and 12 months were observed.
Results
At the final postoperative 12-month period, the average best-corrected visual acuity was 0.4 ± 0.5 in logarithm of the minimum angle of resolution. The mean endothelial cell density at 12 months was 1,841.92 ± 731.24 cells/mm2, indicating no significant endothelial cell loss compared to the baseline (p = 0.128). The mean postoperative central corneal thickness at 12 months was 597.41 ± 86.26 μm. The postoperative mean absolute error at 12 months was 0.96 ± 0.89 diopters (D) and mean error was 0.89 ± 0.97 D.
Conclusions
The results of our South Korean cohort study on UT-DSAEK triple surgery showed favorable and safe outcomes. Regardless of graft thickness, it should be noted that a hyperopic shift of 1.00 to 2.00 D needs to be considered in the case of UT-DSAEK triple surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Zitieren
APA
Koo, M. A., Yoon, H. Y., Park, J. H., Chung, S. H., Kim, H. S., & Byun, Y. S. (2024). One-year Outcomes of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Combined with Cataract Surgery in the Korean Population. Korean Journal of Ophthalmology. https://doi.org/10.3341/kjo.2023.0101
Vancouver
Koo MA, Yoon HY, Park JH, Chung SH, Kim HS, Byun YS. One-year Outcomes of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Combined with Cataract Surgery in the Korean Population. Korean Journal of Ophthalmology. 2024. doi:10.3341/kjo.2023.0101
BibTeX
@article{Koo2024,
author = {Koo, Minjeong Ashley and Yoon, Hye Yeon and Park, Jae Hyun and Chung, So-Hyang and Kim, Hyun-Seung and Byun, Yong-Soo},
title = {One-year Outcomes of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Combined with Cataract Surgery in the Korean Population},
journal = {Korean Journal of Ophthalmology},
year = {2024},
doi = {10.3341/kjo.2023.0101}
}
EUVIMED