Analysis of factors influencing refractive error in Fuchs eyes undergoing Descemet membrane endothelial keratoplasty triple procedure
British Journal of Ophthalmology · 2025
DOI: 10.1136/bjo-2024-325967 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Ophthalmology, 2025. Verfasst von Jenny Chun Ling Kuo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Johns Hopkins University Bloomberg School of Public Health, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Fuchs' Endothelial Dystrophy, Descemet Stripping Endothelial Keratoplasty, Refractive Errors, Lens Implantation, Intraocular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate the accuracy of current intraocular lens (IOL) formulas and identify factors influencing mean error in eyes undergoing Descemet membrane endothelial keratoplasty (DMEK) triple procedure, that is, DMEK combined with cataract extraction and IOL placement for concurrent Fuchs endothelial corneal dystrophy (FECD) and cataracts.
Design
Retrospective cohort study. Subjects 90 eyes with FECD undergoing uncomplicated DMEK triple procedure at Wilmer Eye Institute.
Methods
We analysed tomographic features of oedema, including loss of regular isopachs, displacement of the thinnest point of the cornea and the presence of posterior surface depression, and assessed the correlation with the prediction error. Main outcome measures We compared the mean error (±SD) for the Barrett Universal II (BU2), Hoffer QST, Haigis-L (HL) and Barrett True K (BTK) formulas and the percentage of eyes within 0.25, 0.5 and 1 diopter (D) of error.
Results
All formulas resulted in a mean hyperopic error, with the HL having the lowest mean error of 0.24 D (±0.97 D) and BU2 having the highest ME of 0.94 D (±0.97 D). For each additional tomographic feature of corneal oedema in the BU2 and Hoffer QST formulas, the mean hyperopic error increased by 0.38 D. For the BTK and HL formulas, the mean error increased by 0.35 D (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Johns Hopkins University Bloomberg School of Public Health, Baltimore, Maryland, USA.
- Chang Gung Memorial Hospital Linkou, Taoyuan, Taiwan.
- Ophthalmology, Dankook university Hospital, Cheonan, Chungcheongnam-do, Korea (the Republic of).
- Johns Hopkins Wilmer Eye Institute, Baltimore, Maryland, USA.
- Wilmer Eye Institute, Johns Hopkins Wilmer Eye Institute, Baltimore, Maryland, USA.
- Ophthalmology, University of Virginia, Baltimore, Virginia, USA.
Zitieren
APA
Kuo, J. C. L., Cho, K. J., Ali, M., Jun, A. S., Ladas, J. G., & Srikumaran, D. (2025). Analysis of factors influencing refractive error in Fuchs eyes undergoing Descemet membrane endothelial keratoplasty triple procedure. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2024-325967
Vancouver
Kuo JCL, Cho KJ, Ali M, Jun AS, Ladas JG, Srikumaran D. Analysis of factors influencing refractive error in Fuchs eyes undergoing Descemet membrane endothelial keratoplasty triple procedure. British Journal of Ophthalmology. 2025. doi:10.1136/bjo-2024-325967
BibTeX
@article{Kuo2025,
author = {Kuo, Jenny Chun Ling and Cho, Kyong Jin and Ali, Muhammad and Jun, Albert S and Ladas, John G and Srikumaran, Divya},
title = {Analysis of factors influencing refractive error in Fuchs eyes undergoing Descemet membrane endothelial keratoplasty triple procedure},
journal = {British Journal of Ophthalmology},
year = {2025},
doi = {10.1136/bjo-2024-325967}
}
EUVIMED