Optimizing IOL calculation in triple-DMEK: Data from a real-life cohort
Journal of Optometry · 2025
DOI: 10.1016/j.optom.2025.100551 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Optometry, 2025. Verfasst von Natalia Lorenzana-Blanco und 5 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Department, Fundación Jiménez Díaz University Hospital. Av. de los Reyes Católicos, 2. 28040, Madrid, Spain. Hauptthemen laut MEDLINE: Lenses, Intraocular, Fuchs' Endothelial Dystrophy, Descemet Stripping Endothelial Keratoplasty, Lens Implantation, Intraocular. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
PURPOSE: To enhance the accuracy of intraocular lens (IOL) power calculation in patients with Fuchs' endothelial corneal dystrophy (FECD) undergoing simultaneous cataract surgery and Descemet membrane endothelial keratoplasty (triple-DMEK) by predicting corneal power changes. METHODS: Observational ambispective monocentric cohort study. A linear corneal change model (LCCM) was developed to predict corneal change from the preoperative corneal ratio (anterior/posterior radius). LCCM was validated by comparing prediction errors with the traditional IOL optimization method. RESULTS: 97 eyes of 69 patients were analyzed. Preoperative keratometry was biometrically unmeasurable in 9 eyes, so manually entered autorefractometer data were used for IOL calculations and were analyzed separately. Mean absolute error (MAE) in the manual group (1.35 D (-1.04, 3.75)) was higher than the measured group (0.75 D (-0.62, 2.12)). The median change in simulated keratometry (SimK) was -0.21 ± 0.68 D and in total keratometry (TK) was -0.62 ± 1.09 D (p 0.05). However, MAE for the optimization method was higher (2.08 D (1.77, 2.39)) than LCCM method (1.87 D (1.62, 2.12)). CONCLUSIONS: SimK and TK change significantly after Triple-DMEK. The LCCM could reduce extreme refractive surprises by assisting surgeons in the individualized selection of the best IOL for each eye based on the expected corneal change. Study limitations include variability in FECD severity and the inherent limitations of biometric formulas applied to non-standard eyes. Further studies are recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ophthalmology Department, Fundación Jiménez Díaz University Hospital. Av. de los Reyes Católicos, 2. 28040, Madrid, Spain.
- Ophthalmology Department, Fundación Jiménez Díaz University Hospital. Av. de los Reyes Católicos, 2. 28040, Madrid, Spain. Electronic address: gonzalo.velarde@quironsalud.es.
Zitieren
APA
Lorenzana-Blanco, N., Velarde-Rodríguez, G., Corte-Alonso, S., García-Sandoval, B., Jiménez-Alfaro, I., & Alejandre-Alba, N. (2025). Optimizing IOL calculation in triple-DMEK: Data from a real-life cohort. Journal of Optometry. https://doi.org/10.1016/j.optom.2025.100551
Vancouver
Lorenzana-Blanco N, Velarde-Rodríguez G, Corte-Alonso S, García-Sandoval B, Jiménez-Alfaro I, Alejandre-Alba N. Optimizing IOL calculation in triple-DMEK: Data from a real-life cohort. Journal of Optometry. 2025. doi:10.1016/j.optom.2025.100551
BibTeX
@article{LorenzanaBlanco2025,
author = {Lorenzana-Blanco, Natalia and Velarde-Rodríguez, Gonzalo and Corte-Alonso, Sofía and García-Sandoval, Blanca and Jiménez-Alfaro, Ignacio and Alejandre-Alba, Nicolás},
title = {Optimizing IOL calculation in triple-DMEK: Data from a real-life cohort},
journal = {Journal of Optometry},
year = {2025},
doi = {10.1016/j.optom.2025.100551}
}
EUVIMED