EUVIMEDEUVIMED entdecken
Crossref

A novel multi-dimensional coal and gangue X-ray sorting algorithm based on CdZnTe photon counting detectors

Yang Kang, Rui Wu, Peizheng Li, Qingpei Li, Sen Wu, Tingting Tan, Yingrui Li, Gangqiang Zha

Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · 2024

DOI: 10.3233/xst-230250 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 2024. Verfasst von Yang Kang und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Solidification Processing, and MIIT Key Laboratory of Radiation Detection Materials and Devices, Northwestern Polytechnical U…. Hauptthemen laut MEDLINE: Coal, Tellurium, Cadmium, Zinc. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The gangue content in coal seriously affects the calorific value produced by its combustion. In practical applications, gangue in coal needs to be completely separated. The pseudo-dual-energy X-ray method does not have high sorting accuracy. OBJECTIVE: This study aims to propose a novel multi-dimensional coal and gangue X-ray sorting algorithm based on CdZnTe photon counting detectors to solve the problem of coal and gangue sorting by X-ray. METHODS: This complete algorithm includes five steps: (1) Preferred energy bins, (2) transmittance sorting, (3) one-dimensional R-value sorting, (4) two-dimensional R-value sorting, and (5) three-dimensional R-value sorting. The output range of each step is determined by prior information from 65 groups of coal and gangue. An additional 110 groups of coal and gangue are employed experimentally to validate the algorithm’s accuracy. RESULTS: Compared with the 60% sorting accuracy of the Pseudo-dual-energy method, the new algorithm reached a sorting accuracy of 99%. CONCLUSIONS: Study results demonstrate the superiority of this novel algorithm and its feasibility in practical applications. This novel algorithm can guide other two-substance X-ray sorting applications based on photon counting detectors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CoalTelluriumCadmiumZincX-RaysRadiography

Stichwörter der Autor:innen

CdZnTe detectorX-rayphoton countingsorting algorithm

Substanzen

CdZnTeCoalTelluriumCadmiumZinc

Autor:innen und Institutionen

  • State Key Laboratory of Solidification Processing, and MIIT Key Laboratory of Radiation Detection Materials and Devices, Northwestern Polytechnical University, Xi'an, China.
  • Shenzhen Research Institute of Northwestern Polytechnical University, Shenzhen, China.

Zitieren

APA

Kang, Y., Wu, R., Li, P., Li, Q., Wu, S., Tan, T., Li, Y., & Zha, G. (2024). A novel multi-dimensional coal and gangue X-ray sorting algorithm based on CdZnTe photon counting detectors. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. https://doi.org/10.3233/xst-230250

Vancouver

Kang Y, Wu R, Li P, Li Q, Wu S, Tan T, et al. A novel multi-dimensional coal and gangue X-ray sorting algorithm based on CdZnTe photon counting detectors. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. 2024. doi:10.3233/xst-230250

BibTeX
@article{Kang2024,
  author = {Kang, Yang and Wu, Rui and Li, Peizheng and Li, Qingpei and Wu, Sen and Tan, Tingting and Li, Yingrui and Zha, Gangqiang},
  title = {A novel multi-dimensional coal and gangue X-ray sorting algorithm based on CdZnTe photon counting detectors},
  journal = {Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics},
  year = {2024},
  doi = {10.3233/xst-230250}
}
Kostenlos starten →