First clinical experience of a ring‐configured cadmium zinc telluride camera: A comparative study versus conventional gamma camera systems
Clinical Physiology and Functional Imaging · 2024-01 · 44 (1) · 79-88
DOI: 10.1111/cpf.12853 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Physiology and Functional Imaging, online erschienen am 23.08.2023. Verfasst von Irma Cerić Andelius und 6 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Physics, Skåne University Hospital, Lund/Malmö, Sweden. Hauptthemen laut MEDLINE: Gamma Cameras, Myocardial Perfusion Imaging. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
A novel semiconductor cadmium zinc telluride (CZT) gamma camera system using a block sequential regularized expectation maximization (BSREM) reconstruction algorithm is now clinically available. Here we investigate how a multi‐purpose ring‐configurated CZT system can be safely applied in clinics and describe the initial optimization process.
Method
Seventy‐six patients (bone‐, cardiac‐ and lung scan) were scanned on a conventional gamma camera (planar and/or single‐photon emission computed tomography [SPECT]/SPECT‐CT) used in clinical routine and on the ring‐configurated CZT camera Starguide (GE Healthcare). These data were used to validate and optimize the Starguide system for routine clinical use.
Results
Comparable image quality for the Starguide system, to that of the conventional gamma camera, was achieved for bone scan (4 min/bed position [BP] using a relative difference prior [RDP] with gamma 2 and beta 0.4, along with 10 iterations and 10 subsets), cardiac scan (8 min [stress] and 3 min 20 s [rest] using median root prior [MRP] with beta 0.07 non attenuation corrected and 0.008 attenuation corrected and 50 interations and 10 subsets for both stress and rest) and lung scan (10 min [vent] and 5 min [perf] using RDP with gamma 0.5 and beta 0.03 [vent] and 0.02 [perf] and 20 interations and 10 subsets for both vent and perf).
Conclusions
It was possible to transition from a conventional gamma camera to the Starguide system as part of the clinical routine, with acceptable image quality. Images from the Starguide system were deemed to be at least as good as those from a conventional gamma camera.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Radiation Physics, Skåne University Hospital, Lund/Malmö, Sweden.
- Department of Translational Medicine and Wallenberg Centre of Molecular Medicine, Lund University, Malmö, Sweden.
- Department of Clinical Physiology and Nuclear Medicine, Skåne University Hospital, Lund/Malmö, Sweden.
- Department of Clinical Sciences, Lund University, Lund, Sweden.
Zitieren
APA
Cerić Andelius, I., Minarik, D., Persson, E., Mosén, H., Valind, K., Trägårdh, E., & Oddstig, J. (2024). First clinical experience of a ring‐configured cadmium zinc telluride camera: A comparative study versus conventional gamma camera systems. Clinical Physiology and Functional Imaging, 44(1), 79-88. https://doi.org/10.1111/cpf.12853
Vancouver
Cerić Andelius I, Minarik D, Persson E, Mosén H, Valind K, Trägårdh E, et al. First clinical experience of a ring‐configured cadmium zinc telluride camera: A comparative study versus conventional gamma camera systems. Clinical Physiology and Functional Imaging. 2024;44(1):79-88. doi:10.1111/cpf.12853
BibTeX
@article{CeriAndelius2024,
author = {Cerić Andelius, Irma and Minarik, David and Persson, Eva and Mosén, Henrik and Valind, Kristian and Trägårdh, Elin and Oddstig, Jenny},
title = {First clinical experience of a ring‐configured cadmium zinc telluride camera: A comparative study versus conventional gamma camera systems},
journal = {Clinical Physiology and Functional Imaging},
year = {2024},
volume = {44},
number = {1},
pages = {79--88},
doi = {10.1111/cpf.12853}
}
EUVIMED