EUVIMEDEUVIMED entdecken
Crossref

Dual spectral limited-angle CT imaging regularized by edge-preserving diffusion and smoothing

Yanwei Qin, Yinghui Zhang, Xin Lu, Yunsong Zhao, Xing Zhao

Journal of X-Ray Science and Technology · 2023

DOI: 10.3233/xst-221302 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, 2023. Verfasst von Yanwei Qin und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematical Sciences, Capital Normal University, Beijing, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Limited-angle CT scan is an effective way for nondestructive inspection of planar objects, and various methods have been proposed accordingly. When the scanned object contains high-absorption material, such as metal, existing methods may fail due to the beam hardening of X-rays. In order to overcome this problem, we adopt a dual spectral limited-angle CT scan and propose a corresponding image reconstruction algorithm, which takes the polychromatic property of the X-ray into consideration, makes basis material images free of beam hardening artifacts and metal artifacts, and then helps depress the limited-angle artifacts. Experimental results on both simulated PCB data and real data demonstrate the effectiveness of the proposed algorithm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedImage Processing, Computer-AssistedPhantoms, ImagingX-RaysArtifactsAlgorithms

Stichwörter der Autor:innen

Planar objectsdual spectral limited-angle CT imagingthe high-absorption material

Autor:innen und Institutionen

  • School of Mathematical Sciences, Capital Normal University, Beijing, China.
  • Beijing Advanced Innovation Center for Imaging Technology, Capital Normal University, Beijing, China.
  • Shenzhen National Applied Mathematics Center, Southern University of Science and Technology, Shenzhen, China.

Zitieren

APA

Qin, Y., Zhang, Y., Lu, X., Zhao, Y., & Zhao, X. (2023). Dual spectral limited-angle CT imaging regularized by edge-preserving diffusion and smoothing. Journal of X-Ray Science and Technology. https://doi.org/10.3233/xst-221302

Vancouver

Qin Y, Zhang Y, Lu X, Zhao Y, Zhao X. Dual spectral limited-angle CT imaging regularized by edge-preserving diffusion and smoothing. Journal of X-Ray Science and Technology. 2023. doi:10.3233/xst-221302

BibTeX
@article{Qin2023,
  author = {Qin, Yanwei and Zhang, Yinghui and Lu, Xin and Zhao, Yunsong and Zhao, Xing},
  title = {Dual spectral limited-angle CT imaging regularized by edge-preserving diffusion and smoothing},
  journal = {Journal of X-Ray Science and Technology},
  year = {2023},
  doi = {10.3233/xst-221302}
}
Kostenlos starten →