Image quality improvement in bowtie‐filter‐equipped cone‐beam CT using a dual‐domain neural network
Medical Physics · 2023
DOI: 10.1002/mp.16693 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Sungho Yun und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea. Hauptthemen laut MEDLINE: Quality Improvement, Neural Networks, Computer. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Korean National Research Foundation, Korea Medical Device Development Fund, Ministry of Trade, Industry and Energy.
Abstract (Originalsprache)
Background
The bowtie‐filter in cone‐beam CT (CBCT) causes spatially nonuniform x‐ray beam often leading to eclipse artifacts in the reconstructed image. The artifacts are further confounded by the patient scatter, which is therefore patient‐dependent as well as system‐specific.
Purpose
In this study, we propose a dual‐domain network for reducing the bowtie‐filter‐induced artifacts in CBCT images.
Methods
In the projection domain, the network compensates for the filter‐induced beam‐hardening that are highly related to the eclipse artifacts. The output of the projection‐domain network was used for image reconstruction and the reconstructed images were fed into the image‐domain network. In the image domain, the network further reduces the remaining cupping artifacts that are associated with the scatter. A single image‐domain‐only network was also implemented for comparison.
Results
The proposed approach successfully enhanced soft‐tissue contrast with much‐reduced image artifacts. In the numerical study, the proposed method decreased perceptual loss and root‐mean‐square‐error (RMSE) of the images by 84.5% and 84.9%, respectively, and increased the structure similarity index measure (SSIM) by 0.26 compared to the original input images on average. In the experimental study, the proposed method decreased perceptual loss and RMSE of the images by 87.2% and 92.1%, respectively, and increased SSIM by 0.58 compared to the original input images on average.
Conclusions
We have proposed a deep‐learning‐based dual‐domain framework to reduce the bowtie‐filter artifacts and to increase the soft‐tissue contrast in CBCT images. The performance of the proposed method has been successfully demonstrated in both numerical and experimental studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea.
- KAIST Institute for Artificial Intelligence, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea.
- KAIST Institute for Health Science and Technology, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea.
- KAIST Institute for IT Convergence, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea.
Förderung
- Korean National Research Foundation
- Korea Medical Device Development Fund
- Ministry of Trade, Industry and Energy
- KAI-NEET Institute, KAIST
Zitieren
APA
Yun, S., Jeong, U., Lee, D., Kim, H., & Cho, S. (2023). Image quality improvement in bowtie‐filter‐equipped cone‐beam CT using a dual‐domain neural network. Medical Physics. https://doi.org/10.1002/mp.16693
Vancouver
Yun S, Jeong U, Lee D, Kim H, Cho S. Image quality improvement in bowtie‐filter‐equipped cone‐beam CT using a dual‐domain neural network. Medical Physics. 2023. doi:10.1002/mp.16693
BibTeX
@article{Yun2023,
author = {Yun, Sungho and Jeong, Uijin and Lee, Donghyeon and Kim, Hyeongseok and Cho, Seungryong},
title = {Image quality improvement in bowtie‐filter‐equipped cone‐beam CT using a dual‐domain neural network},
journal = {Medical Physics},
year = {2023},
doi = {10.1002/mp.16693}
}
EUVIMED