Accuracy of analytically determined fractional flow reserve derived from coronary angiography for non-invasive assessment of coronary artery stenosis
Technology and Health Care · 2024-11 · 32 (6) · 4613-4626
DOI: 10.3233/thc-240803 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technology and Health Care, 2024-11. Verfasst von Aleksandar Milovanovic und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Information Technologies, University of Kragujevac, Kragujevac, Serbia. Hauptthemen laut MEDLINE: Coronary Stenosis, Fractional Flow Reserve, Myocardial, Coronary Angiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: Fractional flow reserve (FFR) determined invasively has been globally accepted as the gold standard for determining the functional significance of coronary artery stenoses. However, despite its great importance, the invasive method has certain disadvantages, including the risk of vascular injuries, the need for vasodilation, and significant medical costs. That is why great attention was paid to the development of non-invasive methods that would enable reliable diagnosis without exposing patients to the risk of unwanted consequences. OBJECTIVE: This paper aimed to create and verify an alternative, less resource- and time-demanding, non-invasive solution. METHODS: The determination of FFR is based on the application of the fundamental laws of fluid dynamics. All energy losses in the coronary artery with stenosis were identified and analyzed in detail. A three-dimensional model of a coronary artery was generated using the corresponding angiographic images. Finally, the pressure due to stenosis was calculated and the FFR was determined. RESULTS: The results obtained using the proposed analytical method were compared with available experimental data for 40 patients who experienced the invasive coronary angiography. The coefficient of determination, mean difference and standard deviation values are determined to be 0.726, - 0.017 and 0.056, respectively. These values were slightly higher for FFR values above 0.80. CONCLUSION: The FFR calculated by the proposed analytical method has a relatively good correlation with clinical data, which leads to the conclusion that it can provide a reliable assessment of the functional significance of coronary stenosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Information Technologies, University of Kragujevac, Kragujevac, Serbia.
- Faculty of Engineering, University of Kragujevac, Kragujevac, Serbia.
- Bioengineering Research and Development Center, Kragujevac, Serbia.
Zitieren
APA
Milovanovic, A., Isailovic, V., Saveljic, I., & Filipovic, N. (2024). Accuracy of analytically determined fractional flow reserve derived from coronary angiography for non-invasive assessment of coronary artery stenosis. Technology and Health Care, 32(6), 4613-4626. https://doi.org/10.3233/thc-240803
Vancouver
Milovanovic A, Isailovic V, Saveljic I, Filipovic N. Accuracy of analytically determined fractional flow reserve derived from coronary angiography for non-invasive assessment of coronary artery stenosis. Technology and Health Care. 2024;32(6):4613-4626. doi:10.3233/thc-240803
BibTeX
@article{Milovanovic2024,
author = {Milovanovic, Aleksandar and Isailovic, Velibor and Saveljic, Igor and Filipovic, Nenad},
title = {Accuracy of analytically determined fractional flow reserve derived from coronary angiography for non-invasive assessment of coronary artery stenosis},
journal = {Technology and Health Care},
year = {2024},
volume = {32},
number = {6},
pages = {4613--4626},
doi = {10.3233/thc-240803}
}
EUVIMED