EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access

Accuracy of coronary computed tomography angiography-derived quantitative flow ratio for onsite assessment of coronary lesions

Tingwen Weng, Daixin Ding, Guanyu Li, Shaofeng Guan, Wenzheng Han, Qian Gan, Ming Li, Lin Qi, Cheng Li, Yang Chen, Liang Zhang, Tianqi Li und 5 weitere

EuroIntervention · 2024-10 · 20 (20) · e1288-e1297

DOI: 10.4244/eij-d-24-00336 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift EuroIntervention, 2024-10. Verfasst von Tingwen Weng und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Huadong Hospital Affiliated to Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Coronary Angiography, Coronary Artery Disease, Coronary Stenosis. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Coronary computed tomography angiography (CCTA)-derived Murray law-based quantitative flow ratio (CT-μFR) is a novel non-invasive method for fast computation of fractional flow reserve (FFR) from CCTA images, yet its diagnostic performance remains to be prospectively validated. AIMS: We aimed to evaluate the diagnostic performance of onsite CT-μFR in patients with coronary artery disease. METHODS: This prospective, single-centre trial enrolled patients with ≥1 lesion with 30-90% diameter stenosis on CCTA and planned invasive coronary angiography (ICA) within 30 days. CT-μFR, ICA-derived μFR and FFR were evaluated separately in a blinded fashion. The primary endpoint was the diagnostic accuracy of CT-μFR in identifying patients with haemodynamically significant coronary stenosis defined by the invasive standard: FFR ≤0.80, or μFR ≤0.80 when FFR was not available. RESULTS: Between December 2020 and August 2023, 260 patients were consecutively enrolled. Paired comparison between CT-μFR and the invasive standard was obtained in 706 vessels from 260 patients. The patient-level accuracy of CT-μFR was 89.6% (95% confidence interval [CI]: 85.9-93.4%), which was significantly higher than the prespecified target of 72.0% (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyCoronary AngiographyCoronary Artery DiseaseCoronary StenosisFractional Flow Reserve, MyocardialAgedFemaleHumansMaleMiddle AgedCoronary VesselsPredictive Value of TestsProspective StudiesReproducibility of Results

Autor:innen und Institutionen

  • Department of Cardiology, Huadong Hospital Affiliated to Fudan University, Shanghai, China.
  • Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
  • Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Department of Radiology, Huadong Hospital Affiliated to Fudan University, Shanghai, China.
  • The Lambe Institute for Translational Medicine, the Smart Sensors Laboratory and CURAM, University of Galway, Galway, Ireland.

Zitieren

APA

Weng, T., Ding, D., Li, G., Guan, S., Han, W., Gan, Q., Li, M., Qi, L., Li, C., Chen, Y., Zhang, L., Li, T., Chang, X., Chen, Y., Wijns, W., Qu, X., & Tu, S. (2024). Accuracy of coronary computed tomography angiography-derived quantitative flow ratio for onsite assessment of coronary lesions. EuroIntervention, 20(20), e1288-e1297. https://doi.org/10.4244/eij-d-24-00336

Vancouver

Weng T, Ding D, Li G, Guan S, Han W, Gan Q, et al. Accuracy of coronary computed tomography angiography-derived quantitative flow ratio for onsite assessment of coronary lesions. EuroIntervention. 2024;20(20):e1288-e1297. doi:10.4244/eij-d-24-00336

BibTeX
@article{Weng2024,
  author = {Weng, Tingwen and Ding, Daixin and Li, Guanyu and Guan, Shaofeng and Han, Wenzheng and Gan, Qian and Li, Ming and Qi, Lin and Li, Cheng and Chen, Yang and Zhang, Liang and Li, Tianqi and Chang, Xifeng and Chen, Yankai and Wijns, William and Qu, Xinkai and Tu, Shengxian},
  title = {Accuracy of coronary computed tomography angiography-derived quantitative flow ratio for onsite assessment of coronary lesions},
  journal = {EuroIntervention},
  year = {2024},
  volume = {20},
  number = {20},
  pages = {e1288--e1297},
  doi = {10.4244/eij-d-24-00336}
}
Kostenlos starten →