EUVIMEDEUVIMED entdecken
VergleichsstudieBeobachtungsstudie

Myocardial Perfusion Imaging With PET: A Head-to-Head Comparison of 82 Rubidium Versus 15 O-water Tracers Using Invasive Coronary Measurements as Reference

Simon Winther iD, Laust Dupont Rasmussen, Salma Raghad Karim iD, Jelmer Westra iD, Jonathan Nørtoft Dahl iD, Jacob Hartmann Søby iD, Louise Nissen, Fabian Bøgild Lomstein, Morten Würtz iD, Jens Munch Sundbøll, June Anita Ejlersen iD, Jesper Mortensen und 9 weitere

Circulation: Cardiovascular Imaging · 2025

DOI: 10.1161/circimaging.124.017479 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Circulation: Cardiovascular Imaging, 2025. Verfasst von Simon Winther und 20 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology (S.W., L.D.R., J.N.D., J.H.S., L.N., F.B.L., M.W., J.M.S., M.B.), Gødstrup Hospital, Herning, Denmark. Hauptthemen laut MEDLINE: Coronary Artery Disease, Coronary Circulation, Coronary Stenosis, Coronary Vessels. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Myocardial perfusion imaging by positron emission tomography (PET) is recommended as a first-line test in stable patients with chest pain symptoms and as a selective second-line test after an abnormal coronary computed tomography angiography (CTA). It is, however, unknown whether the use of Rubidium-82 ( 82 Rb) versus [ 15 O]H 2 O ( 15 O-water) affects the diagnostic performance in coronary artery disease (CAD). The aim of this study was to compare 82 Rb-PET versus 15 O-water-PET head-to-head for diagnosing obstructive CAD. METHODS: The study included consecutive patients (n=1000) referred for CTA with symptoms suggestive of obstructive CAD. Patients with suspected stenosis based on CTA were referred for both 82 Rb-PET, 15 O-water-PET, and subsequently invasive coronary angiography (ICA), including 3-vessel fractional flow reserve and coronary flow reserve measurements. RESULTS: In total, 196/270 (73%) patients with suspected stenosis on CTA completed 82 Rb-PET, 15 O-water-PET, and ICA. Myocardial blood flow measurements from 82 Rb-PET and 15 O-water-PET correlated strongly at rest (ρ, 0.62–0.69) but only moderately during hyperemia (ρ, 0.41–0.59). Only weak correlations were demonstrated between myocardial blood flow reserve by both PET tracers compared with ICA coronary flow reserve (ρ, 0.11–0.38). Hemodynamically obstructive CAD defined as ICA fractional flow reserve ≤0.80, was identified in 86/196 (44%) patients. Using predefined cutoffs, the diagnostic accuracies of 82 Rb-PET versus 15 O-water-PET were similar (sensitivity 69% [58–78%] versus 71% [60–80%], P =0.59; specificity 85% [76–91%] versus 77% [68–85%], P =0.12). Using ICA diameter stenoses >70% as a reference, only 48/196 (24%) patients had anatomically severe CAD, and 82 Rb-PET and 15 O-water-PET sensitivities increased to >85%. CONCLUSIONS: For detection of obstructive CAD by PET myocardial perfusion imaging, 82 Rb versus 15 O-water have similar diagnostic performance. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04707859.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary Artery DiseaseCoronary CirculationCoronary StenosisCoronary VesselsMyocardial Perfusion ImagingOxygen RadioisotopesPositron-Emission TomographyRadiopharmaceuticalsRubidium RadioisotopesAgedFemaleHumansMaleMiddle AgedComputed Tomography AngiographyCoronary AngiographyFractional Flow Reserve, MyocardialPredictive Value of TestsWater

Stichwörter der Autor:innen

Rubidiumchest painhemodyamicshumanshyperemia

Substanzen

Oxygen RadioisotopesRadiopharmaceuticalsRubidium RadioisotopesRubidium-82Water

Autor:innen und Institutionen

  • Department of Cardiology (S.W., L.D.R., J.N.D., J.H.S., L.N., F.B.L., M.W., J.M.S., M.B.), Gødstrup Hospital, Herning, Denmark.
  • Institute of Clinical medicine, Aarhus University, Denmark (S.W., S.R.K., J.N.D., J.H.S., L.N., F.B.L., M.W., J.M.S., J.A.E., J.M., L.P.T., H.M.S., N.C.L.H., R.V.J., M.A.M., E.H.C., L.C.G., M.B.).
  • Department of Cardiology, Aalborg University Hospital, Denmark (L.D.R.).
  • Department of Cardiology (S.R.K., J.W., R.V.J., E.H.C.), Aarhus University Hospital, Denmark.
  • Department of Clinical Physiology, Viborg Hospital, Denmark (J.A.E.).
  • Department of Nuclear Medicine (J.M.), Gødstrup Hospital, Herning, Denmark.

ORCID-Profile: Simon Winther, Salma Raghad Karim, Jelmer Westra, Jonathan Nørtoft Dahl, Jacob Hartmann Søby, Morten Würtz, June Anita Ejlersen, Lars Poulsen Tolbod, Mette Nyegaard, Rebekka Vibjerg Jensen, Michael Alle Madsen, Evald Høj Christiansen, Lars Christian Gormsen, Morten Böttcher

Zitieren

APA

Winther, S., Rasmussen, L. D., Karim, S. R., Westra, J., Dahl, J. N., Søby, J. H., Nissen, L., Lomstein, F. B., Würtz, M., Sundbøll, J. M., Ejlersen, J. A., Mortensen, J., Tolbod, L. P., Søndergaard, H. M., Hansson, N. C. L., Nyegaard, M., Jensen, R. V., Madsen, M. A., Christiansen, E. H., …, & Böttcher, M. (2025). Myocardial Perfusion Imaging With PET: A Head-to-Head Comparison of 82 Rubidium Versus 15 O-water Tracers Using Invasive Coronary Measurements as Reference. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.124.017479

Vancouver

Winther S, Rasmussen LD, Karim SR, Westra J, Dahl JN, Søby JH, et al. Myocardial Perfusion Imaging With PET: A Head-to-Head Comparison of 82 Rubidium Versus 15 O-water Tracers Using Invasive Coronary Measurements as Reference. Circulation: Cardiovascular Imaging. 2025. doi:10.1161/circimaging.124.017479

BibTeX
@article{Winther2025,
  author = {Winther, Simon and Rasmussen, Laust Dupont and Karim, Salma Raghad and Westra, Jelmer and Dahl, Jonathan Nørtoft and Søby, Jacob Hartmann and Nissen, Louise and Lomstein, Fabian Bøgild and Würtz, Morten and Sundbøll, Jens Munch and Ejlersen, June Anita and Mortensen, Jesper and Tolbod, Lars Poulsen and Søndergaard, Hanne Maare and Hansson, Nicolaj Christopher Lyng and Nyegaard, Mette and Jensen, Rebekka Vibjerg and Madsen, Michael Alle and Christiansen, Evald Høj and Gormsen, Lars Christian and Böttcher, Morten},
  title = {Myocardial Perfusion Imaging With PET: A Head-to-Head Comparison of 82 Rubidium Versus 15 O-water Tracers Using Invasive Coronary Measurements as Reference},
  journal = {Circulation: Cardiovascular Imaging},
  year = {2025},
  doi = {10.1161/circimaging.124.017479}
}
Kostenlos starten →