Validating the accuracy of the Omron HBP-M4500 blood pressure measuring device according to the ISO81060-2:2018+ Amd 1:2020 protocol

Hakuo Takahashi, Shingo Yamashita, Nobuki Yakura

Technology and Health Care · 2024

DOI: 10.3233/thc-240676 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Technology and Health Care, 2024. Verfasst von Hakuo Takahashi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Biwako Yoikuin Hospital, Shiga, Japan. Hauptthemen laut MEDLINE: Blood Pressure Determination. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Blood pressure (BP) naturally undergoes fluctuations and variations, particularly during anesthesia administration during surgery, hemodialysis, upper and lower gastrointestinal endoscopy, exercise testing, arterial and venous catheterization, and rehabilitation. These changes in BP may lead to life-threatening events. OBJECTIVES: The performance of the Omron HBP-M4500 device in monitoring blood pressure (BP) in the upper arm was validated according to the International Organization for Standardization (ISO) 81060-2:2018+amendment (Amd) 1:2020 protocol. METHODS: The device was used to assess 113 participants in the inflation mode, and 107 participants in the deflation mode. All the patients fulfilled the inclusion criteria, including the arm circumference range and systolic and diastolic BP levels, outlined in the protocol. Data validation and analysis were performed according to the manufacturer’s instructions. RESULTS: In criterion 1, the mean ± standard deviation (SD) values of the differences between the test device and reference BP were -0.6 ± 5.80/2.8 ± 6.78 mmHg (systolic/diastolic) and -1.0 ± 5.35/3.2 ± 6.52 mmHg for the inflation and deflation modes, respectively. These data fulfilled the ISO81060-2:2018+Amd1:2020 requirements of ⩽ 5 ±⁣⩽ 8 mmHg. In criterion 2, the differences were -0.6 ± 4.44/2.8 ± 6.26 and -1.0 ± 3.84/3.2 ± 6.09 mmHg for the inflation and deflation modes, respectively, fulfilling criterion 2 with SD values of ⩽ 6.91 and ⩽ 6.87 for systolic BP and ⩽ 6.34 and ⩽ 6.14 for diastolic BP in the inflation and deflation modes, respectively. These two criteria were fulfilled in both studies. CONCLUSION: The Omron HBP-M4500 device, either in inflation or deflation mode, fulfilled the criteria outlined in the ISO protocol. Therefore, this device is valuable for BP measurement in clinical and hospital settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Pressure DeterminationHumansMaleFemaleMiddle AgedAgedAdultReproducibility of ResultsBlood Pressure MonitorsBlood PressureArm

Stichwörter der Autor:innen

Blood pressure monitoring deviceinternational protocolvalidation study

Autor:innen und Institutionen

  • Department of Cardiology, Biwako Yoikuin Hospital, Shiga, Japan.
  • Department of Technology Development, Omron Healthcare Co., Ltd., Kyoto, Japan.

Zitieren

APA

Takahashi, H., Yamashita, S., & Yakura, N. (2024). Validating the accuracy of the Omron HBP-M4500 blood pressure measuring device according to the ISO81060-2:2018+ Amd 1:2020 protocol. Technology and Health Care. https://doi.org/10.3233/thc-240676

Vancouver

Takahashi H, Yamashita S, Yakura N. Validating the accuracy of the Omron HBP-M4500 blood pressure measuring device according to the ISO81060-2:2018+ Amd 1:2020 protocol. Technology and Health Care. 2024. doi:10.3233/thc-240676

BibTeX
@article{Takahashi2024,
  author = {Takahashi, Hakuo and Yamashita, Shingo and Yakura, Nobuki},
  title = {Validating the accuracy of the Omron HBP-M4500 blood pressure measuring device according to the ISO81060-2:2018+ Amd 1:2020 protocol},
  journal = {Technology and Health Care},
  year = {2024},
  doi = {10.3233/thc-240676}
}
Kostenlos starten →