EUVIMEDEUVIMED entdecken
ValidierungsstudieMultizentrische Studie

Clinical Validation of Photoplethysmography‐Based Finger Cuffless Blood Pressure Monitoring Following European Society of Hypertension Recommendations

Yumin Qiu iD, Zhe Zhou, Jianning Zhang iD, Jiang He iD, Shiyue Xu, Xiaoyu Zhang iD, Ruochen Sun, Chen Su, Wenhao Xia iD, Jun Tao iD

Journal of the American Heart Association · 2026

DOI: 10.1161/jaha.126.050501 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of the American Heart Association, 2026. Verfasst von Yumin Qiu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hypertension and Vascular Disease The First Affiliated Hospital of Sun Yat-sen University Guangzhou Guangdong China. Hauptthemen laut MEDLINE: Photoplethysmography, Hypertension, Blood Pressure, Blood Pressure Monitoring, Ambulatory. Die Arbeit nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cuffless blood pressure (BP) monitoring remains challenging for clinical hypertension management. Although photoplethysmography offers promising solutions for cuffless BP measurement, its clinical validation is limited. This study evaluated the accuracy and clinical utility of photoplethysmography‐based finger cuffless BP monitoring following European Society of Hypertension recommendations.

Methods

The 2‐phase study enrolled 1173 participants. In phase 1 (n=768), a novel photoplethysmography‐based finger cuffless BP monitor was validated against invasive BP, office BP, and 24‐hour ambulatory BP monitoring across 7 European Society of Hypertension–recommended scenarios. In phase 2 (n=405 hypertensive patients), the clinical utility of photoplethysmography‐ versus ambulatory BP monitoring–derived mean systolic BP (SBP), SBP time‐in‐target range, and variability was assessed by examining their associations with hypertension‐mediated organ damage and cardiovascular complications, including arterial stiffness, endothelial dysfunction, coronary heart disease, and stroke.

Results

The photoplethysmography‐based finger cuffless BP monitor fulfilled all validation criteria, with mean differences ≤5 mm Hg and standard deviations ≤8 mm Hg of both systolic and diastolic BP across 7 scenarios, including invasive, static, awake/asleep, device position, treatment, exercise, and recalibration test. Both ambulatory BP monitoring–derived time‐in‐target range and photoplethysmography‐derived mean SBP and time‐in‐target range were significantly associated with endothelial injury and arterial stiffness. Notably, photoplethysmography‐derived mean SBP and time‐in‐target range, but not ambulatory BP monitoring–derived metrics, showed a significant association with coronary artery disease. Furthermore, photoplethysmography‐derived SBP variability was significantly and positively associated with endothelial injury.

Conclusions

Our data demonstrated that the novel photoplethysmography‐based finger cuffless BP monitor reached the criteria of clinical application following European Society of Hypertension recommendations and provided additional clinical implications for the evaluation of hypertension‐mediated organ damage and cardiovascular complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyHypertensionBlood PressureBlood Pressure Monitoring, AmbulatoryBlood Pressure DeterminationHumansFemaleMaleMiddle AgedAgedReproducibility of ResultsEuropePredictive Value of TestsFingersAdultPractice Guidelines as TopicBlood Pressure Monitors

Stichwörter der Autor:innen

European Society of Hypertension recommendationsblood pressure monitoringhypertensionphotoplethysmographytime‐in‐target range

Autor:innen und Institutionen

  • Department of Hypertension and Vascular Disease The First Affiliated Hospital of Sun Yat-sen University Guangzhou Guangdong China.
  • National-Guangdong Joint Engineering Laboratory for Diagnosis and Treatment of Vascular Diseases Guangzhou Guangdong China.
  • National Health Commission Key Laboratory of Assisted Circulation (Sun Yat-sen University) Guangzhou China.
  • Guangxi Hospital Division of The First Affiliated Hospital Sun Yat-sen University Nanning China.

ORCID-Profile: Yumin Qiu, Jianning Zhang, Jiang He, Xiaoyu Zhang, Wenhao Xia, Jun Tao

Zitieren

APA

Qiu, Y., Zhou, Z., Zhang, J., He, J., Xu, S., Zhang, X., Sun, R., Su, C., Xia, W., & Tao, J. (2026). Clinical Validation of Photoplethysmography‐Based Finger Cuffless Blood Pressure Monitoring Following European Society of Hypertension Recommendations. Journal of the American Heart Association. https://doi.org/10.1161/jaha.126.050501

Vancouver

Qiu Y, Zhou Z, Zhang J, He J, Xu S, Zhang X, et al. Clinical Validation of Photoplethysmography‐Based Finger Cuffless Blood Pressure Monitoring Following European Society of Hypertension Recommendations. Journal of the American Heart Association. 2026. doi:10.1161/jaha.126.050501

BibTeX
@article{Qiu2026,
  author = {Qiu, Yumin and Zhou, Zhe and Zhang, Jianning and He, Jiang and Xu, Shiyue and Zhang, Xiaoyu and Sun, Ruochen and Su, Chen and Xia, Wenhao and Tao, Jun},
  title = {Clinical Validation of Photoplethysmography‐Based Finger Cuffless Blood Pressure Monitoring Following European Society of Hypertension Recommendations},
  journal = {Journal of the American Heart Association},
  year = {2026},
  doi = {10.1161/jaha.126.050501}
}