RETRACTED: Technical assessment of shear bond strength at ceramo-alloy interface after various surface treatment combinations and application of metal bonding agent
Technology and Health Care · 2024
DOI: 10.3233/thc-231003 ↗Kurz gefasst
Zurückgezogene Publikation in der Zeitschrift Technology and Health Care, 2024. Verfasst von Nikhil Vitthal Dayama und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics and Crown & Bridge, Career Postgraduate Institute of Dental Science and Hospital, Lucknow, India. Hauptthemen laut MEDLINE: Shear Strength, Surface Properties, Materials Testing. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
BACKGROUND: Bonding between metal and ceramic is one of the most important aspects of a successful prosthesis. Various methods have been recommended for preparing the metal surface to enhance the bond between metal and ceramic including the use of a metal bonding agent. OBJECTIVE: This study aims to evaluate and compare the shear bond strength of the metal-ceramic (M-C) interface after combinations of various surface treatments including the application of a metal bonding agent. METHOD: 40 Ni-Cr alloy specimens were made and divided into 4 groups of 10 each based on the combination of surface treatments. Sandblasting, surface grinding, and Oxidation heat treatment (OHT) were performed on specimens from Group 1 (Control). In addition, Group 2 specimens received ultrasonic cleaning, Group 3 steam cleaning, and Group 4 metal bonding agent application. Following surface treatments on all specimens, porcelain build-up was performed, and shear bond strength was tested in a Digital Universal testing machine. The statistical tests used were independent t-test and ANOVA. RESULTS: Results revealed that Group 4 specimens had the highest mean value of shear bond strength of 39.087 MPa while Group 3 specimens showed the least mean shear bond strength of 18.154 MPa with highly statistically significant results (p< 0.001). CONCLUSION: The surface treatments and application of bonding agent to metal prior to porcelain application resulted in increased shear bond strength of the metal-ceramic interface.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics and Crown & Bridge, Career Postgraduate Institute of Dental Science and Hospital, Lucknow, India.
- Department of Prosthodontics and Crown & Bridge, Saraswati Dental College and Hospital, Lucknow, India.
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
- Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Multidisciplinary Department of Medical-Surgical and Odontostomatological Specialties, University of Campania "Luigi Vanvitelli", Naples, Italy.
Zitieren
APA
Dayama, N. V., Ali, M., Gaur, A., Pandey, K. K., Alqahtani, N. M., Alfarsi, M. A., Zarbah, M. A., Chaturvedi, S., & Minervini, G. (2024). RETRACTED: Technical assessment of shear bond strength at ceramo-alloy interface after various surface treatment combinations and application of metal bonding agent. Technology and Health Care. https://doi.org/10.3233/thc-231003
Vancouver
Dayama NV, Ali M, Gaur A, Pandey KK, Alqahtani NM, Alfarsi MA, et al. RETRACTED: Technical assessment of shear bond strength at ceramo-alloy interface after various surface treatment combinations and application of metal bonding agent. Technology and Health Care. 2024. doi:10.3233/thc-231003
BibTeX
@article{Dayama2024,
author = {Dayama, Nikhil Vitthal and Ali, Mariyam and Gaur, Abhishek and Pandey, Kaushik Kumar and Alqahtani, Nasser M and Alfarsi, Mohammed A and Zarbah, Mohammad A and Chaturvedi, Saurabh and Minervini, Giuseppe},
title = {RETRACTED: Technical assessment of shear bond strength at ceramo-alloy interface after various surface treatment combinations and application of metal bonding agent},
journal = {Technology and Health Care},
year = {2024},
doi = {10.3233/thc-231003}
}
EUVIMED