EUVIMEDAvasta EUVIMED
Crossref

Varus/valgus stability in imageless robotic-assisted total knee arthroplasty applying three-dimensional assessment of varus/valgus stress X-rays

Hiroki Hijikata, Tomoharu Mochizuki, Keisuku Maeda, Osamu Tanifuji, Go Omori, Noriaki Yamamoto, Hiroyuki Kawashima

Bio-Medical Materials and Engineering · 2024

DOI: 10.3233/bme-230146 ↗

At a glance

Journal article in Bio-Medical Materials and Engineering, 2024. Written by Hiroki Hijikata and 6 co-authors. Institution: Division of Orthopaedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medicine and Dental Scienc…. Major MEDLINE topics: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Osteoarthritis, Knee. Cited 2 times so far (Crossref); 24 references.

AbstraktSubjectsBibliograafilised andmedCiteRelated studies

Abstract (original language)

BACKGROUND: The postoperative varus/valgus stability assessment in stress X-rays has been established as an evaluation index. However, it is performed by the two-dimensional (2D) method rather than the three-dimensional (3D) method. OBJECTIVE: This study aimed to identify the precision and reproducibility of measuring varus/valgus stress X-rays three-dimensionally and to examine varus/valgus stability under anesthesia in imageless robotic assisted total knee arthroplasty (rTKA). METHODS: This prospective study analyzed 52 consecutive rTKAs (five males, 67 ± 5.3 years; 47 females, 74 ± 5.9 years). Postoperative varus/valgus stress X-rays in knee extension under anesthesia at manual maximum stress were three-dimensionally assessed by 2D–3D image matching technique using the 3D bone and component models. Varus/valgus angle between components (VV angle) in no stress, valgus stress, varus stress, medial joint opening (MJO), and lateral joint opening (LJO) were evaluated, clarifying this method’s precision and reproducibility and valgus/varus stability. RESULTS: All parameters’ precision and reproducibility had

Subjects

MeSH terms (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresOsteoarthritis, KneeMaleFemaleHumansX-RaysReproducibility of ResultsProspective StudiesKnee Joint

Author keywords

2D–3D image matching techniqueRobotic total knee arthroplastyprecisionreproducibilitystress X ray

Authors and institutions

  • Division of Orthopaedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medicine and Dental Science, Niigata, Japan.
  • Department of Orthopaedic Surgery, Niigata Rehabilitation Hospital, Niigata, Japan.
  • Department of Health and Sports, Niigata University of Health and Welfare, Niigata, Japan.

Cite

APA

Hijikata, H., Mochizuki, T., Maeda, K., Tanifuji, O., Omori, G., Yamamoto, N., & Kawashima, H. (2024). Varus/valgus stability in imageless robotic-assisted total knee arthroplasty applying three-dimensional assessment of varus/valgus stress X-rays. Bio-Medical Materials and Engineering. https://doi.org/10.3233/bme-230146

Vancouver

Hijikata H, Mochizuki T, Maeda K, Tanifuji O, Omori G, Yamamoto N, et al. Varus/valgus stability in imageless robotic-assisted total knee arthroplasty applying three-dimensional assessment of varus/valgus stress X-rays. Bio-Medical Materials and Engineering. 2024. doi:10.3233/bme-230146

BibTeX
@article{Hijikata2024,
  author = {Hijikata, Hiroki and Mochizuki, Tomoharu and Maeda, Keisuku and Tanifuji, Osamu and Omori, Go and Yamamoto, Noriaki and Kawashima, Hiroyuki},
  title = {Varus/valgus stability in imageless robotic-assisted total knee arthroplasty applying three-dimensional assessment of varus/valgus stress X-rays},
  journal = {Bio-Medical Materials and Engineering},
  year = {2024},
  doi = {10.3233/bme-230146}
}
Start for free →