EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Inter‐ and Intra‐Rater Reliability of Pre‐Resection Ligament Tension Assessment Using a Digital Tensioner in Imageless Robotic‐Assisted Total Knee Replacement

Xin Yang, Lingqing Xiao, Pengfei Lei, Rex Wang-Fung Mak iD, Jonathan Patrick Ng, Cham-Kit Wong, Gloria Yan-Ting Lam, Tsz Lung Choi, Mingde Cao iD, Patrick Shu Hang Yung iD, Michael Tim Yun Ong iD

Orthopaedic Surgery · 2026-05 · 18 (5) · 951-957

DOI: 10.1111/os.70299 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthopaedic Surgery, online erschienen am 25.03.2026. Verfasst von Xin Yang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Hong Kong, SAR, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Osteoarthritis, Knee, Ligaments, Articular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Ligament tension balance is essential for successful and long‐term implant survival of total knee arthroplasty (TKA). Conventional manual tensioning methods are subjective and vary with the surgeon experience. This study evaluated the inter‐ and intra‐rater reliability of pre‐resection ligament tension assessments using an imageless robotic‐assisted TKA system.

Methods

In this prospective study, 24 patients (30 knees) with end‐stage knee osteoarthritis underwent CORI‐assisted TKA from September 2024 to February 2025. Three specialist and three trainee surgeons each performed three repeated varus and valgus stress assessments across flexion and extension. Each medial and lateral gap measurement was recorded. Intraclass correlation coefficients (ICCs) were calculated with a two‐way mixed‐effects and two‐way random‐effects model.

Results

Both specialists and trainees demonstrated excellent intra‐ and inter‐ rater reliability (ICC > 0.90) for medial and lateral gaps in extension and medial gap in flexion. Flexion lateral reliability was good‐to‐excellent for trainees (ICC = 0.873, 95% CI: 0.784–0.933) and moderate‐to‐excellent for specialists (ICC = 0.838, 95% CI: 0.729–0.913).

Conclusions

Pre‐resection ligament tension assessment with an imageless robotic system yields high inter‐ and intra‐rater reliability, reducing variability linked to surgeon experience. Digital tensioners may standardize soft tissue balancing in TKA, potentially improving surgical outcomes and reproducibility. Evidence Level Level III, prospective quasi‐experimental study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresOsteoarthritis, KneeLigaments, ArticularHumansProspective StudiesReproducibility of ResultsFemaleMaleAgedObserver VariationMiddle Aged

Stichwörter der Autor:innen

imagelessligament tension assessmentpre‐excisionreliability analysisrobotic‐assisted surgerytotal knee replacement

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Hong Kong, SAR, China.
  • Department of Orthopedic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
  • Department of Orthopaedics and Traumatology, Prince of Wales Hospital, Hong Kong, SAR, China.
  • Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong, SAR, China.

ORCID-Profile: Rex Wang-Fung Mak, Mingde Cao, Patrick Shu Hang Yung, Michael Tim Yun Ong

Zitieren

APA

Yang, X., Xiao, L., Lei, P., Mak, R. W., Ng, J. P., Wong, C. K., Lam, G. Y., Choi, T. L., Cao, M., Yung, P. S. H., & Ong, M. T. Y. (2026). Inter‐ and Intra‐Rater Reliability of Pre‐Resection Ligament Tension Assessment Using a Digital Tensioner in Imageless Robotic‐Assisted Total Knee Replacement. Orthopaedic Surgery, 18(5), 951-957. https://doi.org/10.1111/os.70299

Vancouver

Yang X, Xiao L, Lei P, Mak RW, Ng JP, Wong CK, et al. Inter‐ and Intra‐Rater Reliability of Pre‐Resection Ligament Tension Assessment Using a Digital Tensioner in Imageless Robotic‐Assisted Total Knee Replacement. Orthopaedic Surgery. 2026;18(5):951-957. doi:10.1111/os.70299

BibTeX
@article{Yang2026,
  author = {Yang, Xin and Xiao, Lingqing and Lei, Pengfei and Mak, Rex Wang-Fung and Ng, Jonathan Patrick and Wong, Cham-Kit and Lam, Gloria Yan-Ting and Choi, Tsz Lung and Cao, Mingde and Yung, Patrick Shu Hang and Ong, Michael Tim Yun},
  title = {Inter‐ and Intra‐Rater Reliability of Pre‐Resection Ligament Tension Assessment Using a Digital Tensioner in Imageless Robotic‐Assisted Total Knee Replacement},
  journal = {Orthopaedic Surgery},
  year = {2026},
  volume = {18},
  number = {5},
  pages = {951--957},
  doi = {10.1111/os.70299}
}
Kostenlos starten →