EUVIMEDEUVIMED entdecken
Crossref

Deep Learning–Accelerated 3D T2 CUBE MRI of the Cochlea at 1.5T and 3T: Sonic DL With AIR Recon DL Versus AIR Recon DL Alone

Katherine L Reinshagen, Stacy Hooker, Nisha Nayak, Dominic Juliano, Eugene Milshteyn, Ajeetkumar Gaddipati, Mary Thomas, Dan Rettmann, Ivan Jambor

American Journal of Neuroradiology · 13.11.2026 · ajnr.A9711

DOI: 10.3174/ajnr.a9711 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Neuroradiology, online erschienen am 13.11.2026. Verfasst von Katherine L Reinshagen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Ear Harvard Medical School (K.L.R., S.H., I.J.), Harvard Medical School, GE HealthCare (E.M., M.T.), Boston, MA, USA; GE HealthCare (A.G.), Waukesha,….

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: Three-dimensional fast spin-echo MR cisternography (CUBE) of the internal auditory canal (IAC) and cerebellopontine angle (CPA) requires longer acquisition times that can limit clinical throughput. We evaluated whether a deep learning (DL)-based highly accelerated reconstruction technique, Sonic DL`™ (SDL), combined with a commercially available DL denoising reconstruction (AIR™ Recon DL, ARDL), preserves or improves subjective image quality and cochlear anatomy visualization relative to standard CUBE-ARDL while shortening scan time. MATERIALS AND METHODS: Consecutive patients underwent brain MRI for suspected IAC pathology at 1.5T and 3T with paired acquisition of standard 3D CUBE-ARDL and an accelerated 3D CUBE-SDL sequence. Both used the same voxel size at 1.5T (0.6x0.6x1.2 mm3) and 3T (0.6x0.6x0.6 mm3). Scan times for CUBE-ARDL versus CUBE-SDL were 2:33 versus 1:41 min at 1.5T and 1:55 versus 1:11 min at 3T. Two independent neuroradiologists blinded to MRI acquisition method scored randomized, de-identified images on a 5-point Likert scale across five domains (overall image quality, noise, sharpness, artifacts, cochlear anatomy visualization). Reader-averaged scores for CUBE-ARDL and CUBE-SDL were compared with paired Wilcoxon signed-rank tests, with reader-specific and cumulative link mixed model (CLMM) sensitivity analyses and false discovery rate (FDR) adjustment; intraclass correlation coefficients (ICC) quantified inter-reader reliability for each technique; Gwet's AC2 and weighted (Conger's) kappa with linear ordinal weights quantified pooled inter-reader agreement. RESULTS: After exclusion of 5 training cases per field strength, 49 (1.5T) and 34 (3T) patients were analyzed. CUBE-SDL scored significantly better than CUBE-ARDL for all five domains at both field strengths (all FDR-adjusted P < .001), consistently for each reader and in the CLMM. Inter-reader reliability (ICC) for CUBE-SDL was moderate-to-excellent at 3T (0.63-0.92) and moderate at 1.5T (0.65-0.74), generally exceeding CUBE-ARDL (3T: 0.35-0.61; 1.5T: 0.50-0.71). Pooled inter-reader agreement (Gwet's AC2) ranged from 0.56 to 0.89. CONCLUSIONS: A combined Sonic DL acceleration with ARDL-denoised reconstruction for 3D T2 CUBE produced significantly higher subjective image quality at both 1.5T and 3T, and, at 3T, higher inter-reader reliability than standard CUBE-ARDL, while shortening acquisition time by 34%-38%. These findings support further evaluation, including diagnostic accuracy studies, of CUBE-SDL as an alternative to CUBE-ARDL.

Autor:innen und Institutionen

  • Ear Harvard Medical School (K.L.R., S.H., I.J.), Harvard Medical School, GE HealthCare (E.M., M.T.), Boston, MA, USA; GE HealthCare (A.G.), Waukesha, WI, USA; GE HealthCare (D.R.), Rochester, MN, USA; Wentworth-Douglass…

Zitieren

APA

Reinshagen, K. L., Hooker, S., Nayak, N., Juliano, D., Milshteyn, E., Gaddipati, A., Thomas, M., Rettmann, D., & Jambor, I. (2026). Deep Learning–Accelerated 3D T2 CUBE MRI of the Cochlea at 1.5T and 3T: Sonic DL With AIR Recon DL Versus AIR Recon DL Alone. American Journal of Neuroradiology, ajnr.A9711. https://doi.org/10.3174/ajnr.a9711

Vancouver

Reinshagen KL, Hooker S, Nayak N, Juliano D, Milshteyn E, Gaddipati A, et al. Deep Learning–Accelerated 3D T2 CUBE MRI of the Cochlea at 1.5T and 3T: Sonic DL With AIR Recon DL Versus AIR Recon DL Alone. American Journal of Neuroradiology. 2026:ajnr.A9711. doi:10.3174/ajnr.a9711

BibTeX
@article{Reinshagen2026,
  author = {Reinshagen, Katherine L and Hooker, Stacy and Nayak, Nisha and Juliano, Dominic and Milshteyn, Eugene and Gaddipati, Ajeetkumar and Thomas, Mary and Rettmann, Dan and Jambor, Ivan},
  title = {Deep Learning–Accelerated 3D T2 CUBE MRI of the Cochlea at 1.5T and 3T: Sonic DL With AIR Recon DL Versus AIR Recon DL Alone},
  journal = {American Journal of Neuroradiology},
  year = {2026},
  pages = {ajnr.A9711},
  doi = {10.3174/ajnr.a9711}
}
Kostenlos starten →