Acoustic characteristics of MRI machines (1.5T vs 3T vs 7T) and implications for patient safety

Akriti Dhakal, Sarah Halleluyah Adeyemi, Obiageli Gertrude Nwachukwu, Abhaya Paudel, Oludare Adegbola Owolabi, Julius Ogaga Etuke, Netra Prasad Marasini

INTER-NOISE and NOISE-CON Congress and Conference Proceedings · 20.07.2026 · 273 (2) · 480-489

DOI: 10.3397/nc_2026_0081 ↗

Kurz gefasst

Fachartikel in der Zeitschrift INTER-NOISE and NOISE-CON Congress and Conference Proceedings, erschienen am 20.07.2026. Verfasst von Akriti Dhakal und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic resonance imaging (MRI) systems are among the most intense non-industrial acoustic environments, with sound generation driven by Lorentz-force-induced vibration of gradient coil assemblies during rapid current switching. As MRI technology advances toward higher magnetic field strengths, including 3 Tesla (3T) and ultra-high-field 7 Tesla (7T) systems, acoustic emissions have increased in both magnitude and complexity, raising critical concerns related to high-intensity noise exposure, patient safety, and system design. This study presents a vibroacoustic-focused literature synthesis of MRI systems across 1.5T, 3T, and 7T platforms, examining the coupled electromechanical and structural mechanisms governing noise generation and propagation. Reported sound pressure levels (SPL), spectral characteristics, and sequence-dependent temporal patterns are analyzed to evaluate how magnetic field strength, gradient switching dynamics, and structural resonance contribute to nonlinear amplification of acoustic output. The review further assesses exposure implications using established acoustic metrics, including peak and equivalent sound levels, in relation to existing safety guidelines. Mitigation strategies, including gradient waveform optimization, structural damping, and active and passive noise control approaches, are critically evaluated from an engineering design perspective. The primary contribution of this work is the development of an integrated vibroacoustic framework that links MRI system dynamics with acoustic exposure pathways and safety thresholds, providing a foundation for cross-disciplinary noise control strategies and informing the design of quieter next-generation MRI systems without compromising imaging performance.

Zitieren

APA

Dhakal, A., Adeyemi, S. H., Nwachukwu, O. G., Paudel, A., Owolabi, O. A., Etuke, J. O., & Marasini, N. P. (2026). Acoustic characteristics of MRI machines (1.5T vs 3T vs 7T) and implications for patient safety. INTER-NOISE and NOISE-CON Congress and Conference Proceedings, 273(2), 480-489. https://doi.org/10.3397/nc_2026_0081

Vancouver

Dhakal A, Adeyemi SH, Nwachukwu OG, Paudel A, Owolabi OA, Etuke JO, et al. Acoustic characteristics of MRI machines (1.5T vs 3T vs 7T) and implications for patient safety. INTER-NOISE and NOISE-CON Congress and Conference Proceedings. 2026;273(2):480-489. doi:10.3397/nc_2026_0081

BibTeX
@article{Dhakal2026,
  author = {Dhakal, Akriti and Adeyemi, Sarah Halleluyah and Nwachukwu, Obiageli Gertrude and Paudel, Abhaya and Owolabi, Oludare Adegbola and Etuke, Julius Ogaga and Marasini, Netra Prasad},
  title = {Acoustic characteristics of MRI machines (1.5T vs 3T vs 7T) and implications for patient safety},
  journal = {INTER-NOISE and NOISE-CON Congress and Conference Proceedings},
  year = {2026},
  volume = {273},
  number = {2},
  pages = {480--489},
  doi = {10.3397/nc_2026_0081}
}
Kostenlos starten →