EUVIMEDEUVIMED entdecken
Crossref

AI- assisted compressed sensing for accelerated 1.5T shoulder MRI

Wenle Hu iD, Yizhe Wang, Hongpeng Dong, Junkai Wang, Lixue Wang, Zhongyu Chen, Zhuozhao Zheng

Technology and Health Care · 14.11.2026

DOI: 10.1177/09287329261505631 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology and Health Care, online erschienen am 14.11.2026. Verfasst von Wenle Hu und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Clinical Medicine, Tsinghua University, Beijing, China. Die Arbeit nennt 29 Literaturangaben. Gefördert von: the National Key Research & Development Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Shoulder MRI has relatively long acquisition times. The clinical performance of AI-assisted compressed sensing (ACS) acceleration levels in 1.5-T shoulder MRI remains unclear.

Objective

To compare the acquisition time, image quality, and diagnostic agreement of three clinical shoulder MRI protocols using parallel imaging (PI), ACS4, and ACS8 at 1.5 T. Materials and Methods Prospectively, 158 patients with shoulder discomfort underwent three scanning protocols—the conventional Parallel imaging (PI) protocol, the ACS with a nominal acceleration factor of 4 (ACS4), and the ACS with a nominal acceleration factor of 8 (ACS8), covering four common sequences. Acquisition time, quantitative image quality parameters including True SNR, Relative SNR, Relative CNR, and edge rising distance (ERD), subjective image quality scores from three radiologists, and diagnostic agreement in an exploratory subgroup of 25 patients were assessed.

Results

ACS4 and ACS8 reduce the total acquisition time by approximately 29% and 45%, respectively, compared with the PI protocol while maintaining comparable image quality across evaluated sequences. ACS8 generally demonstrated higher quantitative Relative SNR/CNR values in several tissues and sequences, whereas ACS4 achieved the highest True SNR and subjective image quality scores. ERD differences were not statistically significant, and diagnostic agreement was generally high across protocols.

Conclusion

ACS protocols reduced acquisition time in 1.5-T shoulder MRI, although ACS8 compromised subjective image quality. ACS4 offered a more favorable balance between scanning efficiency and image quality.

Schlagwörter

Stichwörter der Autor:innen

1.5T MRIAI-assisted compressed sensingparallel imaging

Autor:innen und Institutionen

  • School of Clinical Medicine, Tsinghua University, Beijing, China.
  • Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua Medicine, Tsinghua University, Beijing, China.

ORCID-Profile: Wenle Hu

Förderung

  • the National Key Research & Development Program

Zitieren

APA

Hu, W., Wang, Y., Dong, H., Wang, J., Wang, L., Chen, Z., & Zheng, Z. (2026). AI- assisted compressed sensing for accelerated 1.5T shoulder MRI. Technology and Health Care. https://doi.org/10.1177/09287329261505631

Vancouver

Hu W, Wang Y, Dong H, Wang J, Wang L, Chen Z, et al. AI- assisted compressed sensing for accelerated 1.5T shoulder MRI. Technology and Health Care. 2026. doi:10.1177/09287329261505631

BibTeX
@article{Hu2026,
  author = {Hu, Wenle and Wang, Yizhe and Dong, Hongpeng and Wang, Junkai and Wang, Lixue and Chen, Zhongyu and Zheng, Zhuozhao},
  title = {AI- assisted compressed sensing for accelerated 1.5T shoulder MRI},
  journal = {Technology and Health Care},
  year = {2026},
  doi = {10.1177/09287329261505631}
}
Kostenlos starten →