EUVIMEDEUVIMED entdecken
Open Access

Integrated Deep Learning–Based Intracranial Vessel Wall Imaging with DANTE Preparation: Feasibility and Technical Performance

Pranjal Rai, Vincent Ern Yao Chan iD, John C Benson iD, Felix E Diehn iD, Paul M Farnsworth iD, Victoria M Silvera, Peter Kollasch, Alto Stemmer, Marcel Dominik Nickel iD, Steven A Messina iD, Girish Bathla iD

American Journal of Neuroradiology · 2026

DOI: 10.3174/ajnr.a9232 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Neuroradiology, 2026. Verfasst von Pranjal Rai und 10 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Radiology (P.R., V.E.Y.C., J.C.B., F.E.D., P.M.F., V.M.S., S.A.M., G.B.), Mayo Clinic, Rochester, Minnesota raipranjal2@gmail.…. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Intracranial Arterial Diseases, Cerebral Arteries, Magnetic Resonance Angiography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: Although DANTE preparation improves blood suppression in intracranial vessel wall imaging, its integration with deep learning-accelerated T1-SPACE and the resulting lumen-wall image-quality trade-off remain poorly characterized. We evaluated the feasibility and technical performance of integrating a delay alternating with nutation for tailored excitation (DANTE) preparation into a deep learning-accelerated, postcontrast T1-SPACE sequence for intracranial vessel wall imaging (IC-VWI). MATERIALS AND METHODS: In this retrospective, single-center study, 35 patients (22 women; mean age, 57.9 ± 17.1 years) underwent IC-VWI using postcontrast deep learning-T1-SPACE with (T1-SPACEDL+DANTE) and without (T1-SPACEDL) a DANTE preparation. Two neuroradiologists independently scored lumen and wall visualization across the arterial segments on a 4-point Likert scale (1: worst to 4: best) and graded venous flow artifacts along the MCA, perimesencephalic veins (PMV), deep cerebral veins (DCV), and cortical veins (CV). Intersequence comparisons used cumulative-link mixed-effects models (CLMMs); segments were additionally pooled and analyzed as proximal versus distal. Venous flow artifact scores were compared with paired Wilcoxon tests between sequences and percentage agreement between readers. Exploratory Bland-Altman analysis was also performed for both readers. RESULTS: A total of 556 vessel segment pairs were analyzed. In CLMM analysis, T1-SPACEDL+DANTE improved lumen scores versus T1-SPACEDL (pooled OR 40.02; 95% CI 24.06-66.57; false discovery rate [FDR] P < .001) but reduced wall scores (pooled OR 0.11; 95% CI 0.08-0.14; FDR P < .001). By anatomic group, lumen ORs were 26.03 (proximal) and 91.93 (distal), and wall ORs were 0.12 (proximal) and 0.04 (distal) (all FDR P < .001). Venous flow artifacts improved across all analyzed subsites (P < .001). The ±1-point interreader concordance was near perfect across analyses. Bland-Altman plots showed negative lumen bias (favoring T1-SPACEDL+DANTE) and positive wall bias (favoring T1-SPACEDL) without consistent proportional bias. CONCLUSIONS: Adding DANTE preparation to deep learning-accelerated IC-VWI was associated with fewer flow-related artifacts and a clearer depiction of the vessel lumen, which may support a more accurate assessment of intracranial vasculopathies and aneurysms. Potential gains were accompanied by a modest wall-visualization penalty, which is not unexpected with a flow-suppression pulse.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedIntracranial Arterial DiseasesCerebral ArteriesMagnetic Resonance AngiographyRetrospective StudiesHumansMaleFemaleAdultMiddle AgedAgedFeasibility StudiesDeep LearningCerebrovascular Circulation

Autor:innen und Institutionen

  • From the Department of Radiology (P.R., V.E.Y.C., J.C.B., F.E.D., P.M.F., V.M.S., S.A.M., G.B.), Mayo Clinic, Rochester, Minnesota raipranjal2@gmail.com.
  • From the Department of Radiology (P.R., V.E.Y.C., J.C.B., F.E.D., P.M.F., V.M.S., S.A.M., G.B.), Mayo Clinic, Rochester, Minnesota.
  • Siemens Medical Solutions USA (P.K.), Rochester, Minnesota.
  • Research and Clinical Translation (A.S., M.D.N.), Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.

ORCID-Profile: Vincent Ern Yao Chan, John C Benson, Felix E Diehn, Paul M Farnsworth, Marcel Dominik Nickel, Steven A Messina, Girish Bathla

Zitieren

APA

Rai, P., Chan, V. E. Y., Benson, J. C., Diehn, F. E., Farnsworth, P. M., Silvera, V. M., Kollasch, P., Stemmer, A., Nickel, M. D., Messina, S. A., & Bathla, G. (2026). Integrated Deep Learning–Based Intracranial Vessel Wall Imaging with DANTE Preparation: Feasibility and Technical Performance. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a9232

Vancouver

Rai P, Chan VEY, Benson JC, Diehn FE, Farnsworth PM, Silvera VM, et al. Integrated Deep Learning–Based Intracranial Vessel Wall Imaging with DANTE Preparation: Feasibility and Technical Performance. American Journal of Neuroradiology. 2026. doi:10.3174/ajnr.a9232

BibTeX
@article{Rai2026,
  author = {Rai, Pranjal and Chan, Vincent Ern Yao and Benson, John C and Diehn, Felix E and Farnsworth, Paul M and Silvera, Victoria M and Kollasch, Peter and Stemmer, Alto and Nickel, Marcel Dominik and Messina, Steven A and Bathla, Girish},
  title = {Integrated Deep Learning–Based Intracranial Vessel Wall Imaging with DANTE Preparation: Feasibility and Technical Performance},
  journal = {American Journal of Neuroradiology},
  year = {2026},
  doi = {10.3174/ajnr.a9232}
}
Kostenlos starten →