Initial Single‐Centre Experience With the Abbott Pro‐Style Closure Device for Percutaneous Decannulation Following Venoarterial Extracorporeal Membrane Oxygenation Weaning
ANZ Journal of Surgery · 2026
DOI: 10.1111/ans.70445 ↗Kurz gefasst
Fachartikel in der Zeitschrift ANZ Journal of Surgery, 2026. Verfasst von Dushan Miladinovic und 3 weiteren Autor:innen. Beteiligte Einrichtung: Royal Prince Alfred Hospital, Sydney, Australia. Hauptthemen laut MEDLINE: Extracorporeal Membrane Oxygenation, Device Removal, Vascular Closure Devices, Heart Failure. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Themen: Beatmung und Weaning
Abstract (Originalsprache)
Introduction
Venoarterial extracorporeal membrane oxygenation (VA‐ECMO) provides temporary circulatory support for patients with severe cardiac failure. Traditionally, decannulation involves open surgical cut‐down of the common femoral artery, which carries a high risk of wound complications. Percutaneous techniques using vascular closure devices have emerged as a less invasive alternative. This pilot study evaluates the feasibility and early outcomes of a percutaneous VA‐ECMO decannulation technique using the Abbott Pro‐Style closure device, compared with surgical cut‐down.
Methods
A retrospective, single‐centre review was conducted of patients undergoing percutaneous VA‐ECMO decannulation at Royal Prince Alfred Hospital between November 2023 and July 2024. Patients were matched by age and sex to a control group treated with surgical cut‐down. Data included demographics, ECMO indication and duration, procedural characteristics, vascular complications and groin wound outcomes.
Results
The percutaneous technique was performed in 15 patients (mean age 56.7 ± 13.9 years). Technical success was achieved in 87% ( n = 13), with two cases converted to open surgery due to device failure and haemorrhage. Mean procedure time was 74.3 ± 26.3 min versus 101.5 ± 47.2 min for surgical cut‐down ( p = 0.06). Groin wound complication occurred in one percutaneous patient compared to five surgical patients ( p = 0.07). ICU stay and survival to discharge were comparable between the groups.
Conclusion
This early experience supports the feasibility of percutaneous VA‐ECMO decannulation using the Abbott Pro‐Style closure device, with promising signals toward reduced wound complications and shorter procedure times. Larger prospective studies are needed to confirm these preliminary findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Royal Prince Alfred Hospital, Sydney, Australia.
- Department of Vascular Surgery, Royal Prince Alfred Hospital, Sydney, Australia.
ORCID-Profile: Dushan Miladinovic
Zitieren
APA
Miladinovic, D., Borruso, L., Robinson, D. A., & Shiraev, T. (2026). Initial Single‐Centre Experience With the Abbott Pro‐Style Closure Device for Percutaneous Decannulation Following Venoarterial Extracorporeal Membrane Oxygenation Weaning. ANZ Journal of Surgery. https://doi.org/10.1111/ans.70445
Vancouver
Miladinovic D, Borruso L, Robinson DA, Shiraev T. Initial Single‐Centre Experience With the Abbott Pro‐Style Closure Device for Percutaneous Decannulation Following Venoarterial Extracorporeal Membrane Oxygenation Weaning. ANZ Journal of Surgery. 2026. doi:10.1111/ans.70445
BibTeX
@article{Miladinovic2026,
author = {Miladinovic, Dushan and Borruso, Luca and Robinson, David A and Shiraev, Timothy},
title = {Initial Single‐Centre Experience With the Abbott Pro‐Style Closure Device for Percutaneous Decannulation Following Venoarterial Extracorporeal Membrane Oxygenation Weaning},
journal = {ANZ Journal of Surgery},
year = {2026},
doi = {10.1111/ans.70445}
}
EUVIMED