EUVIMEDObjevte EUVIMED
Open access · CC BY-NC-ND 4.0

Displacement of synthetic cranioplasty implant due to mechanical failure of titanium fixation plating: illustrative case

Graham A Branscom iD, Evan M Ren, Michael B Lemonick, Bahie Ezzat iD, Ziad Rifi iD, Shahram Majidi iD, Christopher P Kellner iD, Tomoyoshi Shigematsu iD

Journal of Neurosurgery: Case Lessons · 2026-06-01 · 11 (22)

DOI: 10.3171/case2694 ↗

At a glance

Journal article in Journal of Neurosurgery: Case Lessons, published on 2026-06-01. Written by Graham A Branscom and 7 co-authors. Institution: Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York. 34 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

BACKGROUND Cranioplasty is a common procedure following decompressive craniectomy for traumatic brain injury or stroke, among other reasons, in order to repair a skull defect. Cranioplasty failure is an infrequent occurrence, but in the case of synthetic implants, it is usually caused by infection and incorrect sizing. However, trauma-induced displacement, breakage, and deformities of cranioplasty implants are less common. OBSERVATIONS The authors present a unique case of a cranioplasty failure due to displacement of a polyetheretherketone (PEEK) implant secondary to catastrophic breakage of the titanium fixation plates. The cause of displacement is unknown but is suspected to be trauma. A subsequent review of the literature contextualizes common reasons for failure among synthetic implants and suggests that fracture of synthetic implants or their fixation plates is extremely rare. LESSONS The displacement of a PEEK cranioplasty implant due to breakage of titanium fixation plates is a rare, albeit possible, complication of this neurosurgical procedure. Lifestyle modifications are paramount to reduce trauma risk and resultant cranioplasty failure. The addition of miniplates may also reduce implant displacement risk. Finally, since rates of failure differ by material, careful consideration of the type of material used for the implant should be incorporated into neurosurgical planning. https://thejns.org/doi/10.3171/CASE2694

Subjects

Author keywords

PEEK implantcase reportcranioplasty failuretitanium

Authors and institutions

  • Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York.

ORCID profiles: Graham A Branscom, Bahie Ezzat, Ziad Rifi, Shahram Majidi, Christopher P Kellner, Tomoyoshi Shigematsu

Cite

APA

Branscom, G. A., Ren, E. M., Lemonick, M. B., Ezzat, B., Rifi, Z., Majidi, S., Kellner, C. P., & Shigematsu, T. (2026). Displacement of synthetic cranioplasty implant due to mechanical failure of titanium fixation plating: illustrative case. Journal of Neurosurgery: Case Lessons, 11(22). https://doi.org/10.3171/case2694

Vancouver

Branscom GA, Ren EM, Lemonick MB, Ezzat B, Rifi Z, Majidi S, et al. Displacement of synthetic cranioplasty implant due to mechanical failure of titanium fixation plating: illustrative case. Journal of Neurosurgery: Case Lessons. 2026;11(22). doi:10.3171/case2694

BibTeX
@article{Branscom2026,
  author = {Branscom, Graham A and Ren, Evan M and Lemonick, Michael B and Ezzat, Bahie and Rifi, Ziad and Majidi, Shahram and Kellner, Christopher P and Shigematsu, Tomoyoshi},
  title = {Displacement of synthetic cranioplasty implant due to mechanical failure of titanium fixation plating: illustrative case},
  journal = {Journal of Neurosurgery: Case Lessons},
  year = {2026},
  volume = {11},
  number = {22},
  doi = {10.3171/case2694}
}
Start for free →