EUVIMEDEUVIMED entdecken
Crossref

Nadzor nad mikrobiološkim statusom zraka u zdravstvenoj ustanovi u prostorima za sterilizaciju

Anita Rakić, Katja Ćurin, Ivana Gjeldum

Sigurnost · 2016

DOI: 10.31306/s.58.4.4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sigurnost, 2016. Verfasst von Anita Rakić und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microorganisms in the air are part of the bioaerosol which is composed of different particles of biological substances, dust particles, bacteria cells and their portions, mould spores and a number of by-products of their metabolism. This research focuses on analysing the primary microclimate indicators (temperature and relative humidity) and the presence of microorganisms in the work environment (air). Measurements were taken after the process of sterilisation of infective waste over three months with the objective to determine the total number of aerobic mesophilic bacteria and the total number of moulds. The microclimate indicators were measured with an attested device. The study monitored the microbiological purity of the air in a given place using the sedimentation method, with samples subsequently processed in a microbiology lab in keeping with the prescribed standards. After incubation and following the counting of developed colonies on microbiological substrates (Tryptic soy agar and Sabouraud dextrose agar), different strains of bacteria and moulds were identified. The most common were Gram (+) sporogenes bacteria Micrococcus spp and Staphylococcus spp., and as for fungi the most commonly found were Aspergillus spp and Penicillium spp. It was found that temperature and relative humidity affect the total number of aerobic mesophilic bacteria and fungi which was confirmed using the Wilcoxon equivalent pairs test at the level of statistic significance p

Zitieren

APA

Rakić, A., Ćurin, K., & Gjeldum, I. (2016). Nadzor nad mikrobiološkim statusom zraka u zdravstvenoj ustanovi u prostorima za sterilizaciju. Sigurnost. https://doi.org/10.31306/s.58.4.4

Vancouver

Rakić A, Ćurin K, Gjeldum I. Nadzor nad mikrobiološkim statusom zraka u zdravstvenoj ustanovi u prostorima za sterilizaciju. Sigurnost. 2016. doi:10.31306/s.58.4.4

BibTeX
@article{Raki2016,
  author = {Rakić, Anita and Ćurin, Katja and Gjeldum, Ivana},
  title = {Nadzor nad mikrobiološkim statusom zraka u zdravstvenoj ustanovi u prostorima za sterilizaciju},
  journal = {Sigurnost},
  year = {2016},
  doi = {10.31306/s.58.4.4}
}
Kostenlos starten →