EUVIMEDEUVIMED entdecken
Crossref

Assessment of Area Radiation Dose for the National Cyclotron and PET Centre at Chulabhorn Hospital in Thailand

Phornpailin Pairodsantikul, Paramest Wongsa, Waraporn Sudchai, Nawaporn Wimlopas, Rinrada Kongkhun, Natnaree Fangnok, Nathapol Boonsingma

Journal of Nuclear Medicine Technology · 2024

DOI: 10.2967/jnmt.123.266159 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine Technology, 2024. Verfasst von Phornpailin Pairodsantikul und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Radiological Technology, Faculty of Health Science Technology, HRH Princess Chulabhorn College of Medical Science, Bangkok, Thailand. Hauptthemen laut MEDLINE: Radiation Dosage, Cyclotrons, Hospitals, Positron-Emission Tomography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The National Cyclotron and PET Centre at Chulabhorn Hospital offers nuclear medicine diagnostic services using state-of-the-art digital PET/CT and PET/MRI machines as well as other related devices. Additionally, the center plays a vital role by having a cyclotron to produce radiopharmaceuticals, which are used both in-house and in other hospitals throughout the country. Despite the center's strict adherence to international standards regarding the use of radioactive substances in patients, there remains a potential risk of radiation exposure for operators, workers, and the public due to radioactive contamination and emissions from unsealed sources. Hence, it is imperative to assess and continuously monitor radiation levels in the work area to ensure the utmost level of safety for personnel.

Methods

This study used optically stimulated luminescence dosimeters to measure radiation levels in 17 areas, consisting of 9 controlled and 8 supervised areas. Over a 3-mo period, the average monthly radiation dose was recorded for each location.

Results

The PET/CT room registered the highest radiation dose within the controlled area, with a monthly average of 1.81 ± 0.29 mSv, equivalent to an annual dose of 21.72 mSv. This higher dose can be attributed to the significant number of patients served in this room. In supervised areas, the nursing counter located between the examination room and the patient waiting area exhibited the highest radiation exposure. The average monthly dose measured at this location was 0.085 ± 0.019 mSv, resulting in an annual dose of 1.015 mSv.

Conclusion

The evaluation of radiation dose in controlled and supervised areas indicated that the overall radiation level remains within the prescribed limits. However, the slight excess that was observed at the nursing counter indicates the need for improvement to ensure compliance with the as-low-as-reasonably-achievable principle. Continuous monitoring of radiation levels should be conducted annually to maintain safety standards and minimize the risk that workers and the general public will be exposed to radioactivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageCyclotronsHospitalsPositron-Emission TomographyThailandHumansOccupational Exposure

Stichwörter der Autor:innen

OSL nanoDotnuclear medicineradiation survey

Autor:innen und Institutionen

  • School of Radiological Technology, Faculty of Health Science Technology, HRH Princess Chulabhorn College of Medical Science, Bangkok, Thailand.
  • School of Radiological Technology, Faculty of Health Science Technology, HRH Princess Chulabhorn College of Medical Science, Bangkok, Thailand; paramest.won@cra.ac.th.
  • Thailand Institute of Nuclear Technology, Nakhon Nayok, Thailand; and.
  • National Cyclotron and PET Centre, Chulabhorn Hospital, Bangkok, Thailand.

Zitieren

APA

Pairodsantikul, P., Wongsa, P., Sudchai, W., Wimlopas, N., Kongkhun, R., Fangnok, N., & Boonsingma, N. (2024). Assessment of Area Radiation Dose for the National Cyclotron and PET Centre at Chulabhorn Hospital in Thailand. Journal of Nuclear Medicine Technology. https://doi.org/10.2967/jnmt.123.266159

Vancouver

Pairodsantikul P, Wongsa P, Sudchai W, Wimlopas N, Kongkhun R, Fangnok N, et al. Assessment of Area Radiation Dose for the National Cyclotron and PET Centre at Chulabhorn Hospital in Thailand. Journal of Nuclear Medicine Technology. 2024. doi:10.2967/jnmt.123.266159

BibTeX
@article{Pairodsantikul2024,
  author = {Pairodsantikul, Phornpailin and Wongsa, Paramest and Sudchai, Waraporn and Wimlopas, Nawaporn and Kongkhun, Rinrada and Fangnok, Natnaree and Boonsingma, Nathapol},
  title = {Assessment of Area Radiation Dose for the National Cyclotron and PET Centre at Chulabhorn Hospital in Thailand},
  journal = {Journal of Nuclear Medicine Technology},
  year = {2024},
  doi = {10.2967/jnmt.123.266159}
}
Kostenlos starten →