Finger doses due to 68 Ga-labelled pharmaceuticals in PET departments—results of a multi-centre pilot study

Ann McCann iD, Nicolas Cherbuin, Peter Covens, Jérémie Dabin iD, Sigalit Haruz-Waschitz, Lara Gallo, Hanan Datz, Roel Wierts iD, Malgorzata Wrzesien, Alessandra Zorz, Jennie Cooke, Anita Dowling und 1 weitere

Journal of Radiological Protection · 2023

DOI: 10.1088/1361-6498/acb263 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Radiological Protection, 2023. Verfasst von Ann McCann und 12 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Physics in Health & Medicine, School of Physics, University College, Dublin, Ireland. Hauptthemen laut MEDLINE: Radiopharmaceuticals, Occupational Exposure. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Irish Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Although the use of 68 Ga has increased substantially in nuclear medicine over the last decade, there is limited information available on occupational exposure due to 68 Ga. The purpose of this study is to determine the occupational extremity exposure during the preparation, dispensing and administration of 68 Ga-labelled radiopharmaceuticals.

Method

Workers in eight centres wore a ring dosimeter for all tasks involving 68 Ga-labelled radiopharmaceuticals for a minimum of one month. Additionally, the fingertip dose was monitored in two centres and the hand with the highest ring dose during 68 Ga procedures was also identified in one centre.

Results

The median normalised ring dose for 68 Ga procedures was found to be 0.25 mSv GBq −1 (range 0.01–3.34). The normalised 68 Ga ring doses recorded in this study are similar to that found in the literature for 18 F. This study is consistent with previous findings that the highest extremity dose is found on the non-dominant hand. A limited sub study in two of the centres showed a median fingertip to base of the finger dose ratio of 4.3. Based on this median ratio, the extrapolated annual 68 Ga fingertip dose for 94% of the workers monitored in this study would be below Category B dose limit (150 mSv) and no worker would exceed Category A dose limit (500 mSv).

Conclusion

When appropriate shielding and radiation protection practices are employed, the extremity dose due to 68 Ga is comparable to that of 18 F and is expected to be well below the regulatory limits for the majority of workers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiopharmaceuticalsOccupational ExposureHumansPilot ProjectsPharmaceutical PreparationsFingersPositron-Emission TomographyRadiation Dosage

Stichwörter der Autor:innen

68GaHp(0.07)extremity doseoccupational exposure

Substanzen

RadiopharmaceuticalsPharmaceutical Preparations

Autor:innen und Institutionen

  • Centre for Physics in Health & Medicine, School of Physics, University College, Dublin, Ireland.
  • Department of Medical Physics & Clinical Engineering, St. Vincent's University Hospital, Dublin, Ireland.
  • Institute of Radiation Physics, Lausanne University Hospital (CHUV), Lausanne, Switzerland.
  • In vivo Cellular and Molecular Imaging, Vrije Universiteit Brussel (VUB), Brussels, Belgium.
  • Research in Dosimetric Applications, Belgian Nuclear Research Center (SCK CEN), Mol, Belgium.
  • Department of Medical Physics, Shamir Medical Center, Assaf Harofeh, Israel.

ORCID-Profile: Ann McCann, Jérémie Dabin, Roel Wierts, Robert Kollaard

Förderung

  • Irish Research Council

Zitieren

APA

McCann, A., Cherbuin, N., Covens, P., Dabin, J., Haruz-Waschitz, S., Gallo, L., Datz, H., Wierts, R., Wrzesien, M., Zorz, A., Cooke, J., Dowling, A., & Kollaard, R. (2023). Finger doses due to 68 Ga-labelled pharmaceuticals in PET departments—results of a multi-centre pilot study. Journal of Radiological Protection. https://doi.org/10.1088/1361-6498/acb263

Vancouver

McCann A, Cherbuin N, Covens P, Dabin J, Haruz-Waschitz S, Gallo L, et al. Finger doses due to 68 Ga-labelled pharmaceuticals in PET departments—results of a multi-centre pilot study. Journal of Radiological Protection. 2023. doi:10.1088/1361-6498/acb263

BibTeX
@article{McCann2023,
  author = {McCann, Ann and Cherbuin, Nicolas and Covens, Peter and Dabin, Jérémie and Haruz-Waschitz, Sigalit and Gallo, Lara and Datz, Hanan and Wierts, Roel and Wrzesien, Malgorzata and Zorz, Alessandra and Cooke, Jennie and Dowling, Anita and Kollaard, Robert},
  title = {Finger doses due to 68 Ga-labelled pharmaceuticals in PET departments—results of a multi-centre pilot study},
  journal = {Journal of Radiological Protection},
  year = {2023},
  doi = {10.1088/1361-6498/acb263}
}
Kostenlos starten →