EUVIMEDEUVIMED entdecken
Crossref

Diagnostic Reference Levels in PET Imaging at Chulabhorn Hospital, Thailand

Phornpailin Pairodsantikul, Paramest Wongsa, Chaluntorn Wongkri, Paphawarin Burasothikul, Attapon Jantarato, Chanisa Chotipanich

Journal of Nuclear Medicine Technology · 2024

DOI: 10.2967/jnmt.124.267576 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Medicine Technology, 2024. Verfasst von Phornpailin Pairodsantikul und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Radiological Technology, Faculty of Health Science Technology, HRH Princess Chulabhorn College of Medical Science, Bangkok, Thailand; and. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Hospitals. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diagnostic reference levels (DRLs) are an important tool for controlling radiation exposure and ensuring safety in medical applications. In Thailand, DRL data have been gathered and established for nuclear medicine diagnostics since 2021. However, there is a lack of information on PET imaging examinations. At the National Cyclotron and PET Scan Centre, Chulabhorn Hospital, radiopharmaceuticals are produced for medical imaging and research, and a wide range of PET/CT and PET/MRI examinations are performed. Our objective was to investigate the administered activity of radiopharmaceuticals in patients undergoing PET imaging, especially the existing data on DRLs in medical diagnostic imaging.

Methods

This was a retrospective study on nuclear medicine patients at the National Cyclotron and PET Scan Centre in 2023. Statistical analysis, including the mean and the 75th percentile values, was conducted to determine DRLs according to the International Commission on Radiological Protection guidelines.

Results

The center performed 8,711 PET/CT and PET/MRI studies with 13 protocols in 2023. The most commonly administered activity was 18F-FDG in oncology and neurology examinations, with DRLs of 186.11 and 136.16 MBq, respectively. These values were notably almost twice lower than several reports in other countries.

Conclusion

There is a lack of comprehensive data on most DRLs for PET imaging at this center because of the nonwidespread use of several radiopharmaceuticals. However, the lower DRLs for 18F-FDG can highlight the need for ongoing investigation toward the establishment of local DRLs, as well as assurance on the safety and efficiency of radiation used in nuclear medicine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron-Emission TomographyHospitalsThailandHumansRetrospective StudiesDiagnostic Reference LevelsFemaleMaleAdultMiddle AgedAged

Stichwörter der Autor:innen

PET imagingadministered activitydiagnostic reference levels

Autor:innen und Institutionen

  • School of Radiological Technology, Faculty of Health Science Technology, HRH Princess Chulabhorn College of Medical Science, Bangkok, Thailand; and.
  • School of Radiological Technology, Faculty of Health Science Technology, HRH Princess Chulabhorn College of Medical Science, Bangkok, Thailand; and paramest.won@cra.ac.th.
  • National Cyclotron and PET Centre, Chulabhorn Hospital, Bangkok, Thailand.

Zitieren

APA

Pairodsantikul, P., Wongsa, P., Wongkri, C., Burasothikul, P., Jantarato, A., & Chotipanich, C. (2024). Diagnostic Reference Levels in PET Imaging at Chulabhorn Hospital, Thailand. Journal of Nuclear Medicine Technology. https://doi.org/10.2967/jnmt.124.267576

Vancouver

Pairodsantikul P, Wongsa P, Wongkri C, Burasothikul P, Jantarato A, Chotipanich C. Diagnostic Reference Levels in PET Imaging at Chulabhorn Hospital, Thailand. Journal of Nuclear Medicine Technology. 2024. doi:10.2967/jnmt.124.267576

BibTeX
@article{Pairodsantikul2024,
  author = {Pairodsantikul, Phornpailin and Wongsa, Paramest and Wongkri, Chaluntorn and Burasothikul, Paphawarin and Jantarato, Attapon and Chotipanich, Chanisa},
  title = {Diagnostic Reference Levels in PET Imaging at Chulabhorn Hospital, Thailand},
  journal = {Journal of Nuclear Medicine Technology},
  year = {2024},
  doi = {10.2967/jnmt.124.267576}
}
Kostenlos starten →