EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Peptide-based antifouling aptasensor for cardiac troponin I detection by surface plasmon resonance applied in medium sized Myocardial Infarction

Jia Xin Che, Yi Wu, Shwu Jen Chang, Ching-Jung Chen, Jen-Tsai Liu

Annals of Biomedical Science and Engineering · 2020

DOI: 10.29328/journal.abse.1001007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Biomedical Science and Engineering, 2020. Verfasst von Jia Xin Che und 4 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Highly selective and sensitive detection of cardiac troponin I (cTnI) is a powerful complement to clinical diagnosis of acute myocardial infarction (AMI). In this study, a strategy for cTnI detection was developed by constructing a universal biosensing interface composed of zwitterionic peptides and aptamers. The peptides were self-assembled onto gold chips, and some of them were biotinylated. The cTnI-specific binding aptamers were immobilized through the streptavidin-biotin system. Surface plasmon resonance (SPR) measurements revealed the preparation process. The developed aptasensor presents a linear detection with cTnI ranging from 20 ng/ml to 600 ng/ml and a detection limit of 20 ng/ml. The high immobilization of the aptamer enhances the sensitivity of the aptasensor and the calculated KD was 6.75 nM. Due to the outstanding antifouling property of the zwitterionic peptide, the developed aptasensor possesses a high resistance towards protein fouling. Moreover, the aptasensor has excellent selectivity and specificity towards cTnI in complex media. Hence, the proposed peptide-based aptasensor shows great potential for practical application in medium sized Myocardial Infarction (MI).

Zitieren

APA

Che, J. X., Wu, Y., Chang, S. J., Chen, C., & Liu, J. (2020). Peptide-based antifouling aptasensor for cardiac troponin I detection by surface plasmon resonance applied in medium sized Myocardial Infarction. Annals of Biomedical Science and Engineering. https://doi.org/10.29328/journal.abse.1001007

Vancouver

Che JX, Wu Y, Chang SJ, Chen C, Liu J. Peptide-based antifouling aptasensor for cardiac troponin I detection by surface plasmon resonance applied in medium sized Myocardial Infarction. Annals of Biomedical Science and Engineering. 2020. doi:10.29328/journal.abse.1001007

BibTeX
@article{Che2020,
  author = {Che, Jia Xin and Wu, Yi and Chang, Shwu Jen and Chen, Ching-Jung and Liu, Jen-Tsai},
  title = {Peptide-based antifouling aptasensor for cardiac troponin I detection by surface plasmon resonance applied in medium sized Myocardial Infarction},
  journal = {Annals of Biomedical Science and Engineering},
  year = {2020},
  doi = {10.29328/journal.abse.1001007}
}
Kostenlos starten →