EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Interference-free aptasensor for the sensitive determination of cardiac troponin I: Towards rapid diagnosis of myocardial infarction

Rebecca L. Houston, Eric CY. Law, Emad L. Izake

Sensors and Actuators B: Chemical · 2027-01 · 470 · 140943

DOI: 10.1016/j.snb.2026.140943 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors and Actuators B: Chemical, 2027-01. Verfasst von Rebecca L. Houston und 2 weiteren Autor:innen. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Acute myocardial infarction (AMI) is a leading cause of mortality. Human cardiac troponin I (cTnI) is used as the biomarker for AMI diagnosis. Several assays have been demonstrated for screening cTnI. However, they usually suffer from analytical interference due to the presence of macrotroponin (an immunoglobulin-bound complex) and cardiac troponin T (cTnT) in the sample. This work presents a new sensitive, and selective aptasensor for the interference-free electrochemical determination of cTnI in biological fluids. The sensor is comprised of a screen-printed electrode that is modified with dendritic gold nanostructures and cTnI-specific electroactive aptamer for screening the biomarker by square wave voltammetry (SWV) within 10 min. The new aptasensor demonstrated high sensitivity over the concentration range 0.04 - 50 ng. mL -1 [limit of quantification (LOQ) = 0.04 ng. mL⁻¹ and limit of detection (LOD) = 0.012 ng. mL -1 ]. The sensor showed excellent selectivity towards cTnI over cTnT, macrotroponin, and cTnI antibody molecules. For point-of-care (POC) screening, the aptasensor was integrated with an ultra-compact potentiostat in a lab-on-a-phone assembly and used to determine the biomarker in human serum samples from the Royal College of Pathologists of Australasia Quality Assurance Program (RCPA QAP). The cTnI quantification by the new aptasensor was in excellent agreement with the samples median concentrations that were reported by reference immunoassay method (R 2 = 0.99). These results warrant a large-scale clinical validation trial of this new POC diagnostic for cTnI.

Zitieren

APA

Houston, R. L., Law, E. C., & Izake, E. L. (2027). Interference-free aptasensor for the sensitive determination of cardiac troponin I: Towards rapid diagnosis of myocardial infarction. Sensors and Actuators B: Chemical, 470, 140943. https://doi.org/10.1016/j.snb.2026.140943

Vancouver

Houston RL, Law EC, Izake EL. Interference-free aptasensor for the sensitive determination of cardiac troponin I: Towards rapid diagnosis of myocardial infarction. Sensors and Actuators B: Chemical. 2027;470:140943. doi:10.1016/j.snb.2026.140943

BibTeX
@article{Houston2027,
  author = {Houston, Rebecca L. and Law, Eric CY. and Izake, Emad L.},
  title = {Interference-free aptasensor for the sensitive determination of cardiac troponin I: Towards rapid diagnosis of myocardial infarction},
  journal = {Sensors and Actuators B: Chemical},
  year = {2027},
  volume = {470},
  pages = {140943},
  doi = {10.1016/j.snb.2026.140943}
}
Kostenlos starten →