EUVIMEDEUVIMED entdecken
Crossref

Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction

Jingjing Zhang iD, Lan Wang, Qian Peng, Yongheng Li, Xiyu He iD, Jian Liu, Wei Sun, Lianhui Wang iD, Chunyuan Song iD

ACS Sensors · 12.11.2026

DOI: 10.1021/acssensors.6c03789 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 12.11.2026. Verfasst von Jingjing Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Flexible Electronics (LoFE), Jiangsu Key Laboratory of Smart Biomaterials and Theranostic Technology, Institute of Advanced M…. Die Arbeit nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Nanjing University of Posts and Telecommunications, Qinglan Project of Jiangsu Province of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid clinical decision-making for acute myocardial infarction (AMI) relies on the timely and precise assessment of cardiac biomarkers. However, detecting cardiac troponin I (cTnI), as the gold-standard biomarker for AMI, with both laboratory-grade sensitivity and rapid clinical turnaround remains a formidable challenge in point-of-care (POC) settings. To address this, we develop a one-pot surface-enhanced Raman scattering (SERS) aptasensor that integrates aptamer-mediated cTnI recognition, catalytic hairpin assembly (CHA) amplification, and plasmonic hotspot assembly. The assay supports two kinetic operating modes within the same assay: a 60-min high-sensitivity mode with a serum limit of detection (LOD) of 53.58 fg/mL and a 20-min rapid-triage mode with an LOD of 14.25 pg/mL, below the clinical decision threshold of 40 pg/mL. In a cohort of 100 clinical serum samples, the bootstrap optimism-corrected diagnostic accuracy was 91.3% for the SERS aptasensor, significantly outperforming conventional ELISA (77.8%). In a subset of 94 subjects with available routine cTnT results, the SERS-cTnI assay achieved an area under the receiver operating characteristic curve (AUC) of 0.988, comparable to that of the hospital’s routine chemiluminescence cTnT assay (0.976), supporting its potential as a complementary diagnostic tool for cTnI-based AMI assessment. Furthermore, compatibility with a handheld Raman spectrometer was evaluated in an independent validation cohort (n = 36), achieving 97.2% accuracy using only 4 μL of serum within 20 min following serum preparation. This reliable one-pot SERS platform bridges ultra-sensitive detection and rapid portable readout, holding promise as a potential tool for future decentralized cardiovascular POC diagnostics.

Schlagwörter

Stichwörter der Autor:innen

aptasensorcardiac troponin Icatalytic hairpin assembly (CHA)kinetic readoutpoint-of-care testing (POCT)surface-enhanced Raman scattering (SERS)

Autor:innen und Institutionen

  • State Key Laboratory of Flexible Electronics (LoFE), Jiangsu Key Laboratory of Smart Biomaterials and Theranostic Technology, Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, Na…
  • School of Science, Jiangsu Key Laboratory of Quantum Computing Science and Devices, Nanjing University of Posts and Telecommunications, Nanjing210023, China.
  • Department of Cardiology, Geriatric Hospital of Nanjing Medical University, Nanjing210029, China.
  • Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing210029, China.

ORCID-Profile: Jingjing Zhang, Xiyu He, Lianhui Wang, Chunyuan Song

Förderung

  • National Natural Science Foundation of China
  • Nanjing University of Posts and Telecommunications
  • Qinglan Project of Jiangsu Province of China
  • Natural Science Foundation of Jiangsu Higher Education Institutions of China
  • Basic Research Program of Jiangsu

Zitieren

APA

Zhang, J., Wang, L., Peng, Q., Li, Y., He, X., Liu, J., Sun, W., Wang, L., & Song, C. (2026). Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction. ACS Sensors. https://doi.org/10.1021/acssensors.6c03789

Vancouver

Zhang J, Wang L, Peng Q, Li Y, He X, Liu J, et al. Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction. ACS Sensors. 2026. doi:10.1021/acssensors.6c03789

BibTeX
@article{Zhang2026,
  author = {Zhang, Jingjing and Wang, Lan and Peng, Qian and Li, Yongheng and He, Xiyu and Liu, Jian and Sun, Wei and Wang, Lianhui and Song, Chunyuan},
  title = {Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c03789}
}
Kostenlos starten →