EUVIMEDEUVIMED entdecken
Open Access

Comparing the EMMA capnograph with sidestream capnography and arterial carbon dioxide pressure at 284 kPa

Xavier Ce Vrijdag, Hanna van Waart, Chris Sames, Jamie W Sleigh, Simon J Mitchell

Diving and Hyperbaric Medicine Journal · 2023

DOI: 10.28920/dhm53.4.327-332 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diving and Hyperbaric Medicine Journal, 2023. Verfasst von Xavier Ce Vrijdag und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology, University of Auckland, Auckland, New Zealand. Hauptthemen laut MEDLINE: Carbon Dioxide, Capnography. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Capnography aids assessment of the adequacy of mechanical patient ventilation. Physical and physiological changes in hyperbaric environments create ventilation challenges which make end-tidal carbon dioxide (ETCO2) measurement particularly important. However, obtaining accurate capnography in hyperbaric environments is widely considered difficult. This study investigated the EMMA capnograph for hyperbaric use.

Methods

We compared the EMMA capnograph to sidestream capnography and the gold standard arterial carbon dioxide blood gas analysis in a hyperbaric chamber. In 12 resting subjects breathing air at 284 kPa, we recorded ETCO2 readings simultaneously derived from the EMMA and sidestream capnographs during two series of five breaths (total 24 measurements). An arterial blood gas sample was also taken simultaneously in five participants.

Results

Across all measurements there was a difference of about 0.1 kPa between the EMMA and sidestream capnographs indicating a very slight over-estimation of ETCO2 by the EMMA capnograph, but fundamentally good agreement between the two end-tidal measurement methods. Compared to arterial blood gas pressure the non-significant difference was about 0.3 and 0.4 kPa for the EMMA and sidestream capnographs respectively.

Conclusions

In this study, the EMMA capnograph performed equally to the sidestream capnograph when compared directly, and both capnography measures gave clinically acceptable estimates of arterial PCO2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carbon DioxideCapnographyHumansRespirationRespiration, ArtificialBlood Gas Analysis

Stichwörter der Autor:innen

CapnographyHyperbaric chamberIntensive carePatient monitoring

Substanzen

Carbon Dioxide

Autor:innen und Institutionen

  • Department of Anaesthesiology, University of Auckland, Auckland, New Zealand.
  • Corresponding author: Xavier Vrijdag, Department of Anaesthesiology, School of Medicine, University of Auckland, Private bag 92019, Auckland 1142, New Zealand, x.vrijdag@auckland.ac.nz.
  • Slark Hyperbaric Unit, Waitemata District Health Board, Auckland, New Zealand.
  • Department of Anaesthesia, Waikato Hospital, Hamilton, New Zealand.
  • Department of Anaesthesia, Auckland City Hospital, Auckland, New Zealand.

Zitieren

APA

Vrijdag, X. C., van Waart, H., Sames, C., Sleigh, J. W., & Mitchell, S. J. (2023). Comparing the EMMA capnograph with sidestream capnography and arterial carbon dioxide pressure at 284 kPa. Diving and Hyperbaric Medicine Journal. https://doi.org/10.28920/dhm53.4.327-332

Vancouver

Vrijdag XC, van Waart H, Sames C, Sleigh JW, Mitchell SJ. Comparing the EMMA capnograph with sidestream capnography and arterial carbon dioxide pressure at 284 kPa. Diving and Hyperbaric Medicine Journal. 2023. doi:10.28920/dhm53.4.327-332

BibTeX
@article{Vrijdag2023,
  author = {Vrijdag, Xavier Ce and van Waart, Hanna and Sames, Chris and Sleigh, Jamie W and Mitchell, Simon J},
  title = {Comparing the EMMA capnograph with sidestream capnography and arterial carbon dioxide pressure at 284 kPa},
  journal = {Diving and Hyperbaric Medicine Journal},
  year = {2023},
  doi = {10.28920/dhm53.4.327-332}
}
Kostenlos starten →