Fachartikel in der Zeitschrift Pediatric Pulmonology, 2023. Verfasst von Pablo Cruces und 7 weiteren Autor:innen. Beteiligte Einrichtung: Unidad de Paciente Crítico Pediátrico, Departamento de Pediatría, Hospital El Carmen de Maipú, Santiago, Chile. Hauptthemen laut MEDLINE: Respiratory Distress Syndrome, Carbon Dioxide, Capnography, Breath Holding. Die Arbeit nennt 16 Literaturangaben. Gefördert von: None.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Accurate and reliable noninvasive methods to estimate gas exchange are necessary to guide clinical decisions to avoid frequent blood samples in children with pediatric acute respiratory distress syndrome (PARDS). We aimed to investigate the correlation and agreement between end‐tidal measured immediately after a 3‐s inspiratory‐hold ( PLAT CO 2 ) by capnometry and measured by arterial blood gases (ABG) in PARDS.

Design

Prospective cohort study.

Setting

Seven‐bed Pediatric Intensive Care Unit, Hospital El Carmen de Maipú, Chile. Patients Thirteen mechanically ventilated patients aged ≤15 years old undergoing neuromuscular blockade as part of management for PARDS.

Interventions

None. Measurements and Main Results All patients were in volume‐controlled ventilation mode. The regular end‐tidal (without the inspiratory hold) was registered immediately after the ABG sample. An inspiratory‐hold of 3 s was performed for lung mechanics measurements, recording in the breath following the inspiratory‐hold. ( PLAT CO 2 ). End‐tidal alveolar dead space fraction (AVDSf) was calculated as and its surrogate (S)AVDSf as . Measurements of were considered the gold standard. We performed concordance correlation coefficient (ρc), Spearman's correlation (rho), and Bland–Altmann's analysis (mean difference ± SD [limits of agreement, LoA]). Eleven patients were included, with a median (interquartile range) age of 5 (2–11) months. Tidal volume was 5.8 (5.7–6.3) mL/kg, PEEP 8 (6–8), driving pressure 10 (8–11), and plateau pressure 17 (17–19) cm H 2 O. Forty‐one paired measurements were analyzed. was higher than (52 mmHg [48–54] vs. 42 mmHg [38–45], p < 0.01), and there were no significant differences with PLAT CO 2 (50 mmHg [46–55], p > 0.99). The concordance correlation coefficient and Spearman's correlation between and PLAT CO 2 were robust (ρc = 0.80 [95% confidence interval [CI]: 0.67–0.90]; and rho = 0.80, p < 0.001.), and for were weak and strong (ρc = 0.27 [95% CI: 0.15–0.38]; and rho = 0.63, p < 0.01). The bias between PLAT CO 2 and was −0.4 ± 3.5 mmHg (LoA −7.2 to 6.4), and between and was −8.5 ± 4.1 mmHg (LoA −16.6 to −0.5). The correlation between AVDSf and (S)AVDSf was moderate (rho = 0.55, p < 0.01), and the mean difference was −0.5 ± 5.6% (LoA −11.5 to 10.5).

Conclusion

This pilot study showed the feasibility of measuring end‐tidal CO 2 after a 3‐s end‐inspiratory breath hole in pediatric patients undergoing controlled ventilation for ARDS. Encouraging preliminary results warrant further study of this technique.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiratory Distress SyndromeCarbon DioxideCapnographyBreath HoldingPulmonary Gas ExchangeHumansMaleChildFemaleProspective StudiesChild, PreschoolFeasibility StudiesAdolescentBlood Gas AnalysisInfantRespiration, ArtificialIntensive Care Units, Pediatric

Stichwörter der Autor:innen

acute respiratory distress syndromecapnographycarbon dioxide partial pressurecritical caremechanical ventilation

Substanzen

Carbon Dioxide

Autor:innen und Institutionen

  • Unidad de Paciente Crítico Pediátrico, Departamento de Pediatría, Hospital El Carmen de Maipú, Santiago, Chile.
  • Facultad de Ciencias de la Vida, Universidad Andres Bello, Santiago, Chile.
  • Red Colaborativa Pediátrica de Latinoamérica (LARed Network), Colombia.
  • Departamento de Pediatría, Fundación Universitaria de Ciencias de la Salud, Bogotá, Colombia.
  • Departamento de Pediatría, Universidad Nacional de Colombia, Bogotá, Colombia.
  • Unidad de Investigación y epidemiología clínica, Escuela de Medicina, Universidad Finis Terrae, Santiago, Chile.

ORCID-Profile: Pablo Cruces

Förderung

  • None

Zitieren

APA

Cruces, P., Moreno, D., Reveco, S., Améstica, M., Araneda, P., Ramirez, Y., Vásquez-Hoyos, P., & Díaz, F. (2023). Capnometry after an inspiratory breath hold, PLAT CO 2 , as a surrogate for PaCO2 ${P}_{{\mathrm{aCO}}_{2}}$ in mild to moderate pediatric acute respiratory distress syndrome: A feasibility study. Pediatric Pulmonology. https://doi.org/10.1002/ppul.26610

Vancouver

Cruces P, Moreno D, Reveco S, Améstica M, Araneda P, Ramirez Y, et al. Capnometry after an inspiratory breath hold, PLAT CO 2 , as a surrogate for PaCO2 ${P}_{{\mathrm{aCO}}_{2}}$ in mild to moderate pediatric acute respiratory distress syndrome: A feasibility study. Pediatric Pulmonology. 2023. doi:10.1002/ppul.26610

BibTeX
@article{Cruces2023,
  author = {Cruces, Pablo and Moreno, Diego and Reveco, Sonia and Améstica, Marjorie and Araneda, Patricio and Ramirez, Yenny and Vásquez-Hoyos, Pablo and Díaz, Franco},
  title = {Capnometry after an inspiratory breath hold, PLAT CO 2 , as a surrogate for PaCO2 $P_\mathrmaCO_2$ in mild to moderate pediatric acute respiratory distress syndrome: A feasibility study},
  journal = {Pediatric Pulmonology},
  year = {2023},
  doi = {10.1002/ppul.26610}
}
Kostenlos starten →